Alpine PUR4100 Corporation Eco-Sphere Pump 4100GPH with 33' Cord

User Manual - Page 9

For PUR4100.

PDF File Manual, 11 pages, Read Online | Download pdf file

PUR4100 photo
Loading ...
Loading ...
Loading ...
8
For more information about our company or products, please visit our website at www.alpine4u.com or call us (USA) 1-877-710-0162
OPERATION AND MAINTENANCE
WARNING: Always unplug or disconnect all appliances in the pond from the electrical supply before installing,
repairing, maintaining or handling the equipment in the water.
-Once a week, verify that the pump performance is satisfactory. If you detect a drop in pump performance (such as
a decrease in water ow from the pump or to the waterfall) rst clean the pump’s pre-lter cage and tubing. If the
water ow is still not fully restored to its original performance, clean the rotor impeller and motor casing.
-The pump impeller includes a high quality ceramic shaft that provides long-lasting, reliable performance when
properly maintained. However, extreme care should be taken when handling the shaft during maintenance. Avoid
dropping or pressing too hard on it to avoid breakage or hairline fractures, which may cause the shaft to snap while
in operation.
-This pump is suitable for use in water temperatures from 32 degrees Fahrenheit (0 degrees Celsius) to 95 degrees
Fahrenheit (35 degrees Celsius).
-To keep the pump in long lasting working conditions, always replace any worn parts.
Do not remove the pumps pre-lter cage while operating the pump. Failure to operate the pump without the
pre-lter cage or operating the pump with a broken cage will allow large debris to enter the pump causing damage
to the pump, thus voiding the warranty.
We recommend inspecting your pump on a regular basis to ensure it is functioning properly. If you notice the water
ow rate diminish, it may be due to the pump’s pre-lter cage being blocked with debris. In many cases, the clogged
lter cage can be cleaned by reaching into the pond and pulling the pump out of the water to remove the debris
from the lter cage
Important Note: Always disconnect the power before performing maintenance on the pump. Pull o any debris
stuck to the pump pre-lter cage and/or use a garden hose to spray o any debris stuck to the lter cage.
To avoid shortening the life of the pump, follow these simple maintenance procedures:
Pump Pre-Filter Cage