CAUTION: Discharge the refrigerant system using Freon
TM
Recovery System.If
there is no valve to attach the recovery system, install one (such as a WATCO A-1)
before venting the Freon
TM
. Leave the valve in place after servicing the system.
2.4 REFRIGERATION CYCLE
2.4.1
CONDENSER
Figure 31
1. Remove the cabinet.
2. Remove the 3 screws which fasten the
brace.
3. Remove the 3 screws which fasten the condenser
and shroud.
4. After discharging the refrigerant completely,
unbraze the interconnecting tube at the condenser
connections.
5. Remove the condenser carefully.
6. Re-install the component by referring to notes.
(See Figure 31)
2.4.3 CAPILLARY TUBE
Figure 32
1. Remove the cabinet.
2. Remove the 2 screws which fasten the evaporator.
3. Move the evaporator sideways carefully.
4. After discharging the refrigerant completely,
unbraze the interconnecting tube at the evaporator
connections.
5. Remove the evaporator carefully.
6. Re-install the component by referring to notes.
(See Figure 32)
1. Remove the cabinet.
2. After discharging the refrigerant completely,
unbraze the interconnecting tube at the capillary
tube.
3. Remove the capillary tube.
4. Re-install the component by referring to notes.
2.4.2 EVAPORATOR