General Care and Maintenance
Troubleshooting
To Disable Both Sensors
Turn water on with handle. Hold hands directly over both
sensors for ten (10) seconds. The Ready sensor light will
flash once after five (5) seconds. Continue holding hands
over both sensors until the Ready sensor light flashes
twice. Both sensors are now deactivated. Turn handle off.
To Enable Both Sensors
Turn water on with handle. Hold hands directly over both
sensors for ten (10) seconds. The Ready sensor light will
flash twice, signaling the sensors have been enabled.
Turn handle off.
To Disable the Ready Sensor
Turn water on with handle. Hold hands directly over both
sensors for five (5) seconds. The Ready sensor light will
flash once, signaling that the Ready sensor is disabled.
Turn handle off.
To Enable the Ready Sensor
Turn water on with handle. Hold hands directly over both
sensors for five (5) seconds. The Ready sensor light will
flash once, signaling that the Ready sensor is enabled.
Turn handle off.
Cleaning
Use a soft, damp cloth with mild liquid soap or glass
cleaner. Avoid harsh chemical cleaners, abrasives and
cleaning pads or sponges not specifically designed for
polished surfaces.
Changing Batteries*
When the blue LED indicator at the base of the spout
flashes repeatedly for ten (10) seconds, your batteries
are low. Open the lid on the battery holder to replace
your six (6) AA batteries. [Battery life is approximately
one (1) year.]
Control Box Fitting onto Mounting Shank
Should you experience any clearance issues
trying to mount the control box to the mounting
shank, you will need to contact Moen Consumer
Support at 1-800-BUY-MOEN and order the
optional Wall Mount Service Kit (SKU #177566).
Electronic Start-Up
Should you encounter any issue with your
MotionSense electronics, review the
troubleshooting section found in the instruction sheets included with
your unit. If you no longer have your instructions, they can be viewed as well
as downloaded at moen.com. Moen Customer Support can also assist you at
1-800-BUY-MOEN.
5
* Optional AC Adaptor Service Kit (SKU #177565) available as substitution.
Low battery indicator