6100 series heat pump with backup electric heat
230/208V Models AZ61H07DAD AZ61H09DAD AZ61H12DAD AZ61H15DAD
Capacity
Cooling BTUH 7,000/6,900 9,200/9,100 11,700/11,600 14,300/14,100
EER (BTU/Watt) 12.7/12.7 11.9/11.9 11.4/11.4 10.4/10.4
Dehumidification Pts/Hr 1.7 2.7 3.5 4.5
Features
Refrigerant type R-410A R-410A R-410A R-410A
CFM, indoor fan high 340 360 370 370
CFM, indoor fan low 194 212 284 290
Vent CFM (full open/partial open) 50/40 70/45 75/45 75/45
Power/Ratings
Power factor 91% 92% 92% 91%/92%
Sensible heat ratio @ 230 volts 85% 75% 70% 65%
Cooling Watts 550/530 760/750 980/960 1,345/1,330
Cooling Amperes, F.L. 2.6/2.8 3.5/3.8 4.6/5.0 6.3/6.8
Amperes, L.R. 19.0 21.0 29.5 31.0
Reverse cycle heat BTUH 6,200/6,100 8,100/8,000 10,600/10,400 13,500/13,400
COP 3.9/3.9 3.6/3.6 3.6/3.6 3.2/3.2
Heating Watts 465/440 655/640 855/835 1,200/1,200
Heating Amperes 2.2/2.4 3.1/3.3 4.1/4.5 5.8/6.3
Weight (Net/Ship) 96.8/109.8 104.1/117.1 105.8/118.8 106.0/119.0
265V Models AZ61H07EAD AZ61H09EAD AZ61H12EAD AZ61H15EAD
Capacity
Cooling BTUH 6,900 9,200 11,700 14,300
EER (BTU/Watt) 12.7 11.9 11.4 10.4
Dehumidification Pts/Hr 1.7 2.7 3.5 4.5
Features
Refrigerant type R-410A R-410A R-410A R-410A
CFM, indoor fan high 340 360 370 370
CFM, indoor fan low 194 211 284 290
Vent CFM (full open/partial open) 50/40 70/45 75/45 75/45
Power/Ratings
Power factor 92% 90% 92% 93%
Sensible heat ratio @ 265 volts 85% 75% 70% 65%
Cooling Watts 540 760 1,015 1,355
Cooling Amperes, F.L. 2.2 3.1 4.0 5.4
Amperes, L.R. 12.0 16.5 23.5 26.0
Reverse cycle heat BTUH 6,200 8,200 10,900 13,500
COP 3.9 3.6 3.6 3.2
Heating Watts 455 665 880 1,210
Heating Amperes 2.0 2.7 3.6 5.0
Weight (Net/Ship) 97.0/110.0 106.3/119.3 106.5/119.5 106.3/119.3
Specifications subject to change.
6100 series heat pump with backup electric heat
230/208V Models AZ61H07DAB AZ61H09DAB AZ61H12DAB AZ61H15DAB
Capacity
Cooling BTUH 7,100/6,900 9,400/9,100 11,700/11,600 14,500/14,200
EER (BTU/Watt) 13.0/13.0 12.2/12.2 11.6/11.6 10.6/10.6
Dehumidification Pts/Hr 1.7 2.7 3.5 4.5
Features
Refrigerant type R-410A R-410A R-410A R-410A
CFM, indoor fan high 340 360 370 370
CFM, indoor fan low 194 212 284 290
Vent CFM (full open/partial open) 50/40 70/45 75/45 75/45
Power/Ratings
Power factor 91% 92% 92% 91%/92%
Sensible heat ratio @ 230 volts 85% 75% 70% 65%
Cooling Watts 545/525 755/740 985/965 1,360/1,335
Cooling Amperes, F.L. 2.6/2.8 3.5/3.8 4.6/5.0 6.3/6.8
Amperes, L.R. 19.0 21.0 29.5 31.0
Reverse cycle heat BTUH 6,200/6,100 8,300/8,100 10,600/10,400 13,500/13,400
COP 3.9/3.9 3.7/3.7 3.6/3.6 3.3/3.3
Heating Watts 465/445 650/635 855/835 1,165/1,120
Heating Amperes 2.2/2.4 3.1/3.3 4.1/4.5 5.8/6.3
Weight (Net/Ship) 94.1/107.1 101.4/114.4 102.1/115.1 100.8/113.8
265V Models AZ61H07EAB AZ61H09EAB AZ61H12EAB AZ61H15EAB
Capacity
Cooling BTUH 7,000 9,400 11,700 14,400
EER (BTU/Watt) 12.8 12.2 11.6 10.6
Dehumidification Pts/Hr 1.7 2.7 3.5 4.5
Features
Refrigerant type R-410A R-410A R-410A R-410A
CFM, indoor fan high 340 360 370 370
CFM, indoor fan low 194 211 284 290
Vent CFM (full open/partial open) 50/40 70/45 75/45 75/45
Power/Ratings
Power factor 94% 90% 92% 93%
Sensible heat ratio @ 265 volts 85% 75% 70% 65%
Cooling Watts 545 765 1,000 1,355
Cooling Amperes, F.L. 2.2 3.1 4.0 5.4
Amperes, L.R. 12.0 16.5 23.5 26.0
Reverse cycle heat BTUH 6,200 8,100 10,700 13,500
COP 3.9 3.6 3.6 3.3
Heating Watts 450 655 870 1,165
Heating Amperes 2.0 2.7 3.6 5.0
Weight (Net/Ship) 94.6/107.6 103.6/116.6 103.6/116.6 104.3/117.3
230/208V Models AZ61H07DAC AZ61H09DAC AZ61H12DAC AZ61H15DAC
Capacity
Cooling BTUH 7,100/6,900 9,400/9,100 11,700/11,600 14,500/14,200
EER (BTU/Watt) 13.0/13.0 12.2/12.2 11.6/11.6 10.6/10.6
Dehumidification Pts/Hr 1.7 2.7 3.5 4.5
Features
Refrigerant type R-410A R-410A R-410A R-410A
CFM, indoor fan high 340 360 370 370
CFM, indoor fan low 194 212 284 290
Vent CFM (full open/partial open) 50/40 70/45 75/45 75/45
Power/Ratings
Power factor 91% 92% 92% 91%/92%
Sensible heat ratio @ 230 volts 85% 75% 70% 65%
Cooling Watts 545/525 755/740 985/965 1,350/1,330
Cooling Amperes, F.L. 2.6/2.8 3.5/3.8 4.6/5.0 6.3/6.8
Amperes, L.R. 19.0 21.0 29.5 31.0
Reverse cycle heat BTUH 6,200/6,100 8,300/8,100 10,600/10,400 13,500/13,400
COP 3.9/3.9 3.7/3.7 3.6/3.6 3.3/3.3
Heating Watts 465/445 650/635 855/835 1,190/1,155
Heating Amperes 2.2/2.4 3.1/3.3 4.1/4.5 5.8/6.3
Weight (Net/Ship) 94.1/107.1 102.3/115.3 105.4/118.4 104.5/117.5
265V Models AZ61H07EAC AZ61H09EAC AZ61H12EAC AZ61H15EAC
Capacity
Cooling BTUH 7,000 9,400 11,700 14,400
EER (BTU/Watt) 12.8 12.2 11.6 10.6
Dehumidification Pts/Hr 1.7 2.7 3.5 4.5
Features
Refrigerant type R-410A R-410A R-410A R-410A
CFM, indoor fan high 340 360 370 370
CFM, indoor fan low 194 211 284 290
Vent CFM (full open/partial open) 50/40 70/45 75/45 75/45
Power/Ratings
Power factor 94% 90% 92% 93%
Sensible heat ratio @ 265 volts 85% 75% 70% 65%
Cooling Watts 545 765 1,000 1,355
Cooling Amperes, F.L. 2.2 3.1 4.0 5.4
Amperes, L.R. 12.0 16.5 23.5 26.0
Reverse cycle heat BTUH 6,200 8,100 10,700 13,500
COP 3.9 3.6 3.6 3.3
Heating Watts 450 655 870 1,165
Heating Amperes 2.0 2.7 3.6 5.0
Weight (Net/Ship) 94.6/107.6 104.1/117.1 103.6/116.6 104.7/117.7