AUXILIARY CONTROL SETTINGS (cont)
Mode 3—Freeze Sentinel/Heat Sentinel
The default settings for Mode 3 are:
Heat Sentinel is off
Freeze Sentinel is on.
When Freeze Sentinel is activated, it automatically provides
heat without user interface. This helps to prevent plumbing
damage by turning the heater and indoor fan ON at 41ºF
and OFF at 46ºF.
When Heat Sentinel is activated, it automatically provides
cooling without user interface. This helps to prevent an
excessively hot room by turning the air conditioner ON
at 85ºF and OFF at 80ºF.
NOTE: These functions are active whenever the unit is
plugged in, even if the unit is in the STOP position.
Mode 4—Constant ON Fan
The default setting for Mode 4 is OFF.
Mode 5—Temperature Limiting
The default setting for Mode 5 is as follows:
Cool: 2 (66ºF to 85ºF)
Heat: 5 (60ºF to 78ºF)
Temperature limitsCool Temperature limits—Heat
0 = 60°F to 85°F 0 = 60°F to 65°F
1 = 64°F to 85°F 1 = 60°F to 70°F
2 = 66°F to 85°F 2 = 60°F to 72°F
3 = 68°F to 85°F 3 = 60°F to 74°F
4 = 70°F to 85°F 4 = 60°F to 76°F
5 = 72°F to 85°F 5 = 60°F to 78°F
6 = 74°F to 85°F 6 = 60°F to 80°F
7 = 76°F to 85°F 7 = 60°F to 85°F
Mode 6Remote Thermostat – Class 2
The default setting for Mode 6 is OFF.
Setting this mode to ON will allow the unit to operate
with a Class 2 Remote Control Wall Thermostat.
Mode 7Duct Mode
The default setting for Mode 7 is OFF.
This setting is used when the unit is installed using
a duct adapter kit. If the unit is ducted, the Duct Mode
needs to be set to ON. This increases the fan speed to
ensure proper circulation.
Mode 8—All-Electric Heat (AZ6100 only)
The default setting for Mode 8 is OFF.
This electric heat option functions only on the 6100 model.
When this option is ON, heat pump operation is locked out,
causing the unit to provide only electric resistance heat.
Mode 9Heat Boost (AZ6100 only)
The default setting for Mode 9 is OFF.
When Heat Boost is ON and outer temperatures are
between 25ºF and 46ºF, heat pump-only operation is locked
out. This setting is used to provide supplementary heat to the
heat pump operation by electric resistance heat in conditions
where the heat pump-only operation is not sufficient to
maintain a consistent, comfortable room temperature.
NOTE: Heat Boost option should NOT be used with remote
thermostat operation. This will cause the unit to switch to
resistance heat when the outdoor temperature is 4F.
Press “Mode”
Press
/
HEAT
COOL
Freeze Sentinel – Off
Freeze Sentinel – On
Press “Mode”
Press
/
HEAT
COOL
Heat Sentinel – Off
Heat Sentinel – On
Press “Mode”
Press
/
Constant Fan – Off
Constant Fan – On
Press “Mode”
Press
/
Duct Mode – Off
Duct Mode – On
Press “Mode”
Press
/
ALL 12R Mode – Off
ALL 12R Mode – On
Press “Mode”
Press
/
Boost Heat – Off
Boost Heat – On
Press “Mode”
Press
/
HEAT
COOL
Temperature Limit Cool
Press “Mode”
Press
/
Class 2 Mode – Off
Class 2 Mode – On
0: 60F-85F
1: 64F-85F
2: 66F-85F
3: 68F-85F
4: 70F-85F
5: 72F-85F
6: 74F-85F
7: 76F-85F
Press “Mode”
Press
/
HEAT
COOL
Temperature Limit Heat
0: 60F-65F
1: 60F-70F
2: 60F-72F
3: 60F-74F
4: 60F-76F
5: 60F-78F
6: 60F-80F
7: 60F-85F