2.1. ENVIRONMENT THE APPLIANCE
SHOULD BE PLACED
•The appliance must not be placed on a base
•There must be sufficient natural air ventilation in the room for gas
combustion for the appliance to function correctly.
•The air flow should enter through grilled air vents in the outer walls.
•Air grills must have a cross section of 100 cm² for the passage of air and
for appliances with a flame safety device. For appliances with no flame
safety device, this cross section should be 200 cm². (Single or multiple
grills can be used)
Emission of Combustion Gases
•Combustion gases from cooking appliances must be released directly out
of doors or via a hood connected to a chimney or flue (Figure 1)
•If it is impossible to install a hood, an electric extraction fan should be fitted
in a wall or a window opening out of doors (Figure 2)
•Extractor fans should have a capacity of replacing kitchen air 3- 5 times
per hour.
Figure 1 Figure 2
•This grill(s) should be constructed so that it cannot be closed from
either side and positioned preferably near the floor. Grill(s) must not be
placed across the channels through which combustion gases and
exhausted fumes pass.
•If it is impossible to install grilled air vents in the room where the
appliance is installed, the air needed can also be supplied from an
adjacent room providing it is not a bedroom or a room where an air
current could cause danger.
750 mm
400 mm
200 mm 200 mm
20 mm
20 mm
2.2. POSITIONING
This appliance is “Class 2.1”. The appliance has been designed on
the presumption that the adjacent work tops will be no higher than the
cook top surface.
2.3. FEET ADJUSTMENT
•The maximum height of cooker will be 920mm by fixing the adjustable
feet.
Your appliance has adjustable feet at the lower corners of its chassis.
•The feet can be adjusted individually with the aid of a wrench to
guarantee that the oven is perfectly balanced and levelled, so that any
liquids in the pans is horizontal .
2.4. ELECTRICAL CONNECTION
Cookers can be presented with or without enrgy cable. Cable
connection should be done by Autorited service according to
following instructions.
The electrical connection must be made according to the standards
and regulations in force. Before making the electrical connection,
check the following:
•Is the capacity of the electrical connections and safety fuses in the
building sufficient to cope with the load of the appliance? (Check with
the adhesive info label)
•Does the electricity supply line have an earth connection conforming
with the standards in force? A proper earth connection must exist in
your home. If there is not a proper earth connection at your home,
please apply to an authorized technician to deal with this problem.
•Is the socket or the multi-pole switch at a easily reachable point after
the installation of the appliance?
•A plug conforming to standards should be connected to the mains
cable and the cable should be inserted into a safe socket.
•A multi-pole switch must be used between the appliance and the
electricity line if a direct electrical connection to the appliance is
required. (It must comply with standards and be appropriate for the
load)
The green-yellow ground cable must not be interrupted by a switch.
The brown phase cable (from the “L" coded connector of the oven)
must always be connected to the phase line of the mains.
•The power line must be positioned so that it is not exposed to
temperatures higher than 50° C.
•When the power cable must be changed, a cable with a cross section
appropriate to the indicated power must be used. The green-yellow
ground cable should be approximately 2 cm longer than phase and
neutral cables.
•Check the heaters by switching them on for 3 minutes, after having
completed the connection.
•The manufacturer will not accept responsibility for damages
arising due to non-compliance with the safety standards.
•For the direct connection to the fixed wiring, it’s nessessary to provide
means for disconnection from the supply mains having a contact
separation in all poles that provide full disconnection under
overvoltage category III conditions, in accordance with the wiring
rules