Loading ...
Loading ...
Loading ...
Installation and connection en
23
Before using your appliance
for the first time
1. Remove leaflets, adhesive tape and
protective film.
2. Clean the appliance.
~ "Cleaning" on page 28
Electrical connection
Caution!
Do not connect the appliance to
electronic energy saver plugs.
Note: You can connect the appliance
to mains-controlled and sine-controlled
inverters.
Mains-controlled inverters are used for
photovoltaic systems which are
connected directly to the national grid.
Sine-controlled inverters must be used
for isolated applications. Isolated
applications, e.g. on ships or in
mountain lodges, which are not
connected directly to the national grid.
1. After installing the appliance, wait at
least 1 hour before connecting it to
prevent damaging the compressor.
2. Connect the appliance via a
correctly installed socket.
The socket must comply with the
following data:
Outside Europe: Check whether the
indicated current type of the
appliance corresponds with the
values of your power supply.
Appliance specifications are on the
rating plate.
3. Connect the appliance to a socket
near the appliance.
The socket must be freely
accessible even after the appliance
has been installed.
Socket with 220 V ... 240 V
Conductor 50 Hz
Fuse 10 A ... 16 A
Loading ...
Loading ...
Loading ...