NOTE: Install this system when the primary pump will not be required.
1. Start by finding the water level at which your primary pump starts. Mark this point on the
discharge pipe with a pencil or marker.
2. NOTE: If your existing discharge pipe is metal or flexible tubing it will need to be replaced
with Schedule 40 PVC or ABS pipe.
3. Drain as much excess water from the sump pit as possible.
4. When the basin has been drained, turn off the power to the outlet / pump to avoid the risk of
electrical shock.
5. Before removing the primary pump, make sure the discharge pipe is properly supported to
prevent it from collapsing.
6. If your installation uses a flexible pipe coupling with clamps, simply disconnect the coupling
and remove the pump. If a flexible coupling is not used, cut the pipe using a hacksaw at any
convenient location above the floor and remove the pump from the basin NOTE: BE
PREPARED FOR WATER TO LEAK FROM THE PIPE WHEN CUTTING. Keep tools and
components of this system away from the work area when cutting pipe. If any components
get wet, make sure they are dry before installing.
7. If your primary pump does not have a check valve in or near the pump discharge, install one
at this time (not provided). It is necessary to have a check valve installed on both the back
up pump and on the primary pump. The primary pump check valve must be located below
the junction of where the back up and primary piping meet. This is to prevent backflow from
the back-up pump when it is running.
8. Attach the back-up pump to the primary discharge pipe using two U-Bolts, Clamps, washers
and nuts (G). Position the pump so it is located near the water level that was marked in
Step 1. Tighten nuts using a 10mm socket or adjustable wrench. DO NOT over tighten.
NOTE: Make sure the U-bolts are properly seated in the recessed areas on the pump
mounting bracket. (The pump mounting bracket comes pre-attached to the pump).
A. Primary Pump
B. Back up Pump
C. Check Valve
D. Female Adapter
E. 45° Street Elbow
F. Wye fitting
G. U-Bolts & Clamps
H. Float Switch Clamp
I. Primary pump check valve
(not included)
FIGURE 1 FIGURE 1
33
GARANTÍA LIMITADA Y LIMITACIÓN DE RESPONSABILIDAD
Decko Products garantiza que este producto estará libre de defectos de materiales y
manufactura durante un año a partir de la fecha de compra. Como único y exclusivo remedio
por el incumplimiento de esta garantía limitada, si Decko Products determina que el producto
tiene defectos, Decko Products, a su discreción, reembolsará el precio de compra o
reemplazará el producto por otro equivalente si el producto es devuelto al lugar de compra o
con franqueo pagado a Decko Products, ATTN: Warranty Dept., 2301 Traffic St. NE, Minneap-
olis, MN 55413, acompañado por el comprobante de compra. Todo desarmado,
modificación o abuso de este producto anulará esta garantía limitada. Este producto no
está diseñado para bombear líquidos inflamables o corrosivos, y el uso de este producto
para bombear dichos materiales también anulará esta garantía limitada
DECKO PRODUCTS RENUNCIA A TODAS LAS DEMÁS GARANTÍAS
EXPLÍCITAS O IMPLÍCITAS, INCLUIDAS LAS GARANTÍAS DE
COMERCIABILIDAD O DE IDONEIDAD PARA UN FIN ESPECÍFICO.
AVISO IMPORTANTE: Algunas pólizas de seguros comerciales y residenciales proveen
cobertura extendida para daños incurridos por averías de productos. En la mayoría de
los casos, usted necesitará el producto en su poder para apoyar su reclamación. Si
necesita conservar el producto para apoyar una reclamación por daños enviada a una
aseguradora, Decko Products reemplazará la unidad o reembolsará el precio original
después de que se resuelva la reclamación con la aseguradora