Installation: Product Specications
Location Limitations: The product is designed to be
installed indoors, in a controlled environment. Air
cooled models discharge very warm air into the room
out the back. Space must be allowed at the left side
and back for air intake and discharge.
Water cooled models discharge warm water into the
building’s drain. Space needs to be provided on both
sides and above for service access.
Space Limitations - Affects Ice Making Capacity
Note: Although the machine will function, ice capacity
of air cooled machines will be signicantly reduced
with minimal clearance at the sides, back and
top. Some space is recommended for service and
maintenance purposes on all models.
6" of space at the sides and back are required for
adequate operation. To get the most capacity, locate
the machine away from heat producing appliances
and heating ducts. Provide several feet of space to
the left for maximum ice capacity.
Walls or other large machines near to the ice machine
might also cause a reduction in ice capacity. One foot
behind and two feet above will be required to make
rated capacity.
Airow is in the front, in the left side, out the back (as
viewed from the front).
Environmental Limitations
Minimum Maximum
Air temperature 50
o
F. 100
o
F.
Water
temperature
40
o
F. 100
o
F.
Water pressure 20 psi 80 psi
Power supply – acceptable voltage ranges
Minimum Maximum
208-230 volt
model
198 volts 253 volts
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for applicable
coverage. In general warranty covers defects
in material or workmanship. It does not cover
maintenance, corrections to installations, or situations
when the machine is operated in circumstances that