C1448, C1848 E
Air and Water Cooled User Manual
December 2014
Page 10
Drains
All models require drain tubing to be attached to them.
Air cooled models have a single ¾” FPT drain tting
in the back of the cabinet. Water cooled models have
the same tting plus an additional ½” FPT drain tting
in the back of the cabinet. Install new tubing when
replacing a prior ice machine, as the tubing will have
been sized for the old model and might not be correct
for this one.
1. Connect water supply to water inlet ttings.
Note: This NSF listed model has a 1" anti-back
ow air gap between the end of the water inlet tube
and the highest possible reservoir water level, no
additional back ow device is required for the potable
water inlet.
2. Connect drain tubing to drain ttings.
3. Route the drain tubing to building drain. Follow
local codes for air gap.
Use rigid drain tubes and then route them separately
– do not Tee into the bin’s drain or, if water cooled,
Tee the condenser drain into the reservoir or bin drain.
Vent the reservoir drain. A vertical vent at the back of
the drain, extended about 8 – 10” will allow the gravity
drain to empty and also keep any surges during
draining from discharging water.
Horizontal runs of drain tubing need a ¼” per fall per
foot of run for proper draining. Follow all applicable
codes.
Water Supply and Drain Connections
Water Inlet
Connection
Potable
Water
Supply
Floor Drain
Water Cooled
Condenser
Inlet
Water Cooled
Condenser
Drain
Optional Water
Filters
Reservoir
Drain