PRODUCT DATA SHEETS
Standard Interior Water Filtration System Model WFI-NL200/NL200
Capacity : 200 gallons (757 liters),
Service flow rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
Cyst Interior Water Filtration System Model WFI-NLC200/NLC200
Capacity: 200 gallons (757 liters),
Service flow rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
It is essential that operational, maintenance, and filter
replacement requirements be carried out for this product to
perform as advertised.
Model NL200 Change cartridge at least every 6-9 months.
Use replacement cartridge NL200, part# 8171413. 2002
suggested retail price of $29.95 U.S.A./$39.95 Canada. Prices
are subject to change without notice.
Model NLC200 Change the cartridge at least every 6-9
months. Use replacement cartridge NLC200, part# 8171414.
2002 suggested retail price of $39.95 U.S.A./$49.95 Canada.
Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before
or after the system. Systems certified for cyst reduction
may be used on disinfected water that may contain
filterable cysts.
Refer to the “Assistance or Service” section for the
Manufacturer’s name, address and telephone number.
Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Substance
Reduction
U.S. EPA
MCL
Average
Influent
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
NSF Test
Number
Chlorine, Taste/Odor N/A 2.0 mg/L N/A 0.02 mg/L N/A 99% 994715
Substance Reduction
Aesthetic Effects
Chlorine Taste/Odor
Particulate
U.S. EPA
MCL
N/A
N/A
Average
Influent
1.9 mg/L
108,667/mL*
Maximum
Effluent
N/A
N/A
Average
Effluent
0.06 mg/L
45/mL
Minimum %
Reduction
N/A
N/A
Average %
Reduction
97%
99.96%
NSF Test
Number
994707
994711
Contaminant
Reduction
U.S. EPA
MCL
Average
Influent
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
NSF Test
Number
Cyst
Turbidity
99.95%**
N/A
157,750/mL
26 NTU
55/mL
0.5 NTU
1.0/mL
0.1 NTU
99.9987%
98.9%
99.9996%
99.5%
994710
994710
Lead: @ pH 6.5
Lead: @ pH 8.5
0.015 mg/L
0.015 mg/L
0.160 mg/L***
0.158 mg/L***
0.011 mg/L
0.011 mg/L
0.001 mg/L
0.001 mg/L
93.5%
92.1%
99.4%
99.3%
994708
994709
Tested and certified by NSF International against ANSI/NSF
Standard 42 for the reduction of Chlorine (Class I), Taste and Odor.
Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
City or Well
30 - 120 psig (207 - 827 kPa)
33° - 100°F (0.6° - 37.8° C)
*
**
***
Test requirement is at least 100,000 particles/ml of AC Fine Test Dust.
Cyst performance is % reduction based on NSF Standard 53.
Test requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water
conditions.
® NSF is a registered trademark of NSF International.