User manual Dehumidifier
1. Control panel
2. Handles (both sides)
3. Water bucket
4. Water level indicator
5. Air outlet
6. Air filter
7. Continuous drain outlet
8. Power cord storage strap
9. Power cord storage band
10. Power cord
11. Pump drain outlet


Auto Off
Auto On
The auto on and auto off timers can be used at the same time by first setting one and then the other.
For example, if the dehumidifier is running, you can set the auto off timer to let it run for a set amount of time before turning off and then set the auto on timer to turn it back on at a later time.
Or, if the dehumidifier is not running, you can set the auto on timer to turn it on at a later time and then set the auto off timer to shut it off after running for a period of time.
Note: The timer will not cycle the dehumidifier on and off indefinitely. The auto on and auto off timers will function one time and then the dehumidifier will return to regular functioning.
Turning the dehumidifier on or off at any time or changing the timer setting to 0.0 will cancel the timer settings.
There are three ways to remove collected water from the appliance.
1. Water Bucket
The dehumidifier will automatically collect condensed water in the water bucket. When the bucket is full, the compressor and fan will turn off and the full bucket indicator light will turn on. The display will show “P2”.
To empty the bucket, gently remove it from the appliance by gripping both sides and pulling outward. Be cautious when removing the bucket, it will be full and can be heavy.
Do not place the water bucket directly on the floor. The bottom of the bucket is uneven and it will fall over and spill water.
Empty the bucket and replace it in the appliance. The dehumidifier will not function without the bucket installed.
Never tamper with or attempt to defeat the water level float system. Proper installation of the water bucket is crucial in maintaining reliable operation.
Note: When removing the bucket, the pump arm for the drain pump may fall down. It must be gently pushed upward back into the correct position before replacing the bucket.

2. Continuous Drain
Water can be removed using the provided connector and drain hose.
Before using any automatic drain functions, check that all drain ports are clean. There is one drain port inside the bucket compartment of the appliance, remove the bucket to see it. There is one drain port on the back of the appliance where the drain hose attaches. All drain ports should be cleaned with a pipe cleaner prior to use.
Remove the cover from the continuous drain outlet and attach the provided connector and drain hose to the back of the appliance. Direct the other end of the drain hose to a bucket or floor drain.
Ensure that the drain hose is not bent and goes straight down from the back of the appliance. The continuous drain is only activated by gravity so any bends or upward motion in the hose will stop the water from draining.
The drain hose is 2 m (6.6 feet) long. Do not connect this drain hose together with any other hose. If the drain hose is too long water may not drain completely which can lead to stagnant water and mildew build up inside the hose.
Notes:
3. Pump Drain
If the continuous drain is inconvenient, water can be removed from the appliance using the pump drain.
When using the pump, the appliance will first fill the bucket with water and then the pump arm will pump water from the bucket through the drain and out the hose.
Remove the continuous drain hose from the unit and rotate back plastic cover to the continuous drain hose outlet clockwise.
Peel off the fixed tape, insert the pump drain hose into the pump drain hose outlet for depth of 15 mm at least, and make sure the hose is secure so there are no leaks.
Direct the other end of the hose to a drain. Press the pump button to activate the pump function. When the bucket is full, the pump will begin to work.
Ensure that the drain hose is not bent, this can stop the water from draining correctly and overwork the pump.
Do not connect the provided hose together with another hose. The maximum length of the pump drain hose should be no more than 4.6 m (15 feet). If the drain hose is too long water may not drain completely which can lead to stagnant water and mildew build up inside the hose.
When using the pump drain, the water bucket should be emptied every few days to ensure that the water in the bucket does not become stagnant or grow mildew.
To remove the hose, press inward on the ring around the drain and pull the hose outward.
Important: If the drain pump is activated, water will exit the drain whether a hose is attached or not. Ensure that the drain pump is deactivated when the hose is removed to avoid damage to floor due to leaking water.
The air filter should be cleaned approximately every 2 weeks. The air filter may require more frequent cleaning if there is significant dander or fur in the air.
Approximately every two weeks, the filter indicator light on the control panel will illuminate as a reminder to clean the filter. Follow the steps below to clean the filter and return the appliance to normal functioning.
Note: Do not operate the appliance without the air filter installed.
If the display panel shows any of the below error codes, unplug the appliance, let it stand for 5-10 minutes and then plug it back in. If the error persists, call for service.
AS - Humidity sensor error
ES - Temperature sensor error
P2 - Full bucket
Eb - bucket removed or not in the correct position
To avoid possible electric shock, ensure that the appliance is unplugged before performing any cleaning or maintenance.
The outside of the appliance can be wiped clean with a soft cloth or with a lukewarm, damp cloth if necessary.
Do not use gasoline, benzene, thinner or any other chemicals to clean this appliance as these substances can cause damage to the finish and deformation of plastic parts.
Never pour water directly onto the appliance as this will cause deterioration of electrical components and wiring insulation.
Ensure that the drain ports on the interior of the appliance and the drain ports on the back of the appliance are free of dirt and calcium build up.
Unplug the dehumidifier and ensure the filter is clean. Ensure the bucket is empty and then allow both the bucket and the dehumidifier to dry completely before storing for the off season. It could take a few days for water inside the dehumidifier to completely evaporate. You can speed up this process by wiping the bucket with a dry cloth and ensuring the lower drain of the dehumidifier has been emptied. Store the dehumidifier covered in a dry location.
This appliance may not be treated as regular household waste, it should be taken to the appropriate waste collection point for recycling of electrical components. Check for local regulatory compliance regarding approved and safe disposal of this appliance.
What is the best humidity setting?
Is the air that comes out of the dehumidifier supposed to be hot?
Why isn’t the dehumidifier collecting any water?
Does the fan run continuously?
Can I use an extension cord?
Does the timer cycle on and off forever?
How do I hook up my direct drain?
Does the filter light come on when it is dirty?
What is the plastic piece in the bucket?
Appliance will not operate
Insufficient dehumidifying
Noise
Odors
Water on floor
Frost build up
Reference file: Danby DDR050BJPWDB-ME-6 50 Pint Dehumidifier with Pump
Additionally, the document applies to other Danby models: DDR050BJPWDB-ME