Conversion to another type of gas
*INSTALLATION*
61
Checking operation
Check all gas fittings for leaks.
Reassemble the cooktop.
Ignite all burners to check that they
are operating correctly.
- The flame must not go out on the
lowest setting, or when the control is
turned quickly from the highest to the
lowest setting.
- On the highest setting, the flame
must have a distinctive and visible
core.
Adhere the label supplied with the
jets over the old label stating the type
of gas being used.