Conversion to another type of gas
*INSTALLATION*
58
Risk of explosion due to an
incorrect conversion.
If the conversion to another type of
gas is carried out incorrectly, it may
result in gas leakage.
Conversion from one type of gas to
another must only be undertaken by
an authorised and registered gas
installer in strict accordance with
current local and national safety and
building regulations. The installer is
responsible for ensuring that the
appliance functions correctly when
installed. Disconnect the cooktop
from the electricity supply and turn
off the gas supply.
Jet table
The jet markings refer to a ¹/₁₀₀mm
bore diameter.
Main jet Small jet
NG
Auxiliary
burner
0.90 0.52
Semi-rapid
burner
1.10 0.52
Rapid burner 1.43 0.60
Wok burner 2x 1.27 / 0.90 0.44
ULPG
Auxiliary
burner
0.52 0.23
Semi-rapid
burner
0.66 0.36
Rapid burner 0.81 0.44
Wok burner 2x 0.70 / 0.46 0.25