12
en Troubleshooting
Cleaning the base unit
Never immerse the base unit in liquids
or hold under running water and do not
clean in the dishwasher. Do not steam-
clean the appliance.
Wipe the base unit with a damp cloth.
If required, use a little detergent.
Then dry the base unit.
Cleaning the bowl, tools and
accessories
It is recommended rinsing all parts
under running water immediately after
use.
Take accessories apart before cleaning.
Do this in reverse order as described in
the individual chapters.
After cleaning, allow all parts to dry
thoroughly or rub dry.
Taking the stirring whisk apart for
cleaning
The stirring whisk can be taken apart for
cleaning.
X Fig. L
1. Remove the stirring whisk from the gear.
2. Push in the lug and lift off the gear
cover.
3. Remove both gear wheels from the
housing. Clean carefully with a brush.
4. After cleaning and drying, re-assemble
all parts in reverse order.
Cleaning the blender
The blender jug (without the blade insert),
lid and funnel are dishwasher-proof. Do not
clean the blade insert in the dishwasher but
under running water (do not soak in water).
Taking the blade insert apart for cleaning
X Fig. M
1. Turn the empty blender jug over. Rotate
the blade insert anti-clockwise by the
wings. The blade insert will release.
2. Take the blade insert out and remove
the sealing ring.
3. After cleaning and drying, fit the sealing
ring to the blade insert.
4. Fit the blade insert into the blender
jug from below and rotate clockwise
to secure. Rotate the blade insert at
least until the wing matches up with the
marking on the blender jug.
Caution!
Never use the blade insert without the seal.
Cleaning the universal cutter
It is recommended cleaning the universal
cutter immediately after use. This will
prevent residues from drying on and
possibly attacking the plastic (e.g. essential
oils in herbs). Do not clean the jug with the
drive in the dishwasher but under running
water using a brush. Do not leave in water.
To dry, place the jug with the drive facing
up.
Troubleshooting
W Risk of injury!
Before dealing with any faults, disconnect
the mains plug.
Important information:
The illuminated ring (operation indicator)
will flash if there is an error in operation,
the electronic fuses have tripped or the
appliance has a defect.
Fault:
Appliance is no longer working.
Possible cause:
The appliance has been overloaded
(e.g. tool jammed by food) and the
electronic fuse has tripped.
Remedial action:
Set rotary switch to P.
Disconnect the mains plug.
Eliminate the cause of the overload.
Switch the appliance back on again.