GE - General Electric PTDN800EMWW GE Profile Harmony 7.3 Cu. Ft. Stainless Steel Capacity Electric Dryer

User Manual - Page 20

For PTDN800EMWW.

PDF File Manual, 76 pages, Read Online | Download pdf file

PTDN800EMWW photo
Loading ...
Loading ...
Loading ...
CONNECTING A GAS DRYER (cont.)
Installation Instructions
20
TEST FOR LEAKS
WARNING – Never use an open
flame to test for gas leaks.
Check all connections for leaks with soapy solution
or equivalent.
Apply a soap solution. The leak test solution must
not contain ammonia, which could cause damage
to the brass fittings.
If leaks are found, close the valve, retighten the joint
and repeat the soap test.
Open Gas
Valve
ELECTRICAL CONNECTION
INFORMATION FOR GAS DRYERS
WARNING – To reduce the risk of
fire, electric shock and personal injury:
Do not use an extension cord or an adapter plug
with this appliance.
The dryer must be electrically grounded in
accordance with local codes and ordinances, or
in the absence of local codes, in accordance with
the NATIONAL ELECTRICAL CODE, ANSI/NFPA
NO. 70.
ELECTRICAL REQUIREMENTS
FOR GAS DRYERS
This appliance must be supplied with 120V, 60Hz,
and connected to a properly grounded branch
circuit, protected by a 15- or 20-amp circuit breaker
or time-delay fuse.
If electrical supply provided does not meet the
above specifications, it is recommended that a
licensed electrician install an approved outlet.
WARNING – This dryer is
equipped with a three-prong (grounding) plug for
your protection against shock hazard and should
be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove
the grounding terminal from this plug.
Ensure proper
ground exists
before use.
Loading ...
Loading ...
Loading ...