TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE
No power A fuse may be blown or the circuit breaker
tripped
Plug not fully inserted into the wall outlet
Internal temperature not cold enough
Appliance runs continuously
Alarm sounding and “HI” on the display panel
Alarm indicator light is illuminated
Door is not shut properly or opened excessively
Exhaust vent is obstructed
Recently added a large quantity of warm bottles
to the cabinet
Close proximity to heat source or direct sunlight
Ambient temperature or humidity is very high
Possible system leak, evaporator fan failure or
compressor failure
Demo mode is active
The actuator on the bottom of the door is not
making contact with the switch on the cabinet
Condensation on the cabinet or door Door is not shut properly or opened excessively
Ambient temperature or humidity is very high
Alarm sounding and “LO” on the display panel
Alarm indicator light is illuminated
Ambient temperature is excessively low
• Sensor failure
Evaporator temperature is too low
Display is not functioning and interior light will
not turn on
The appliance may be operating in energy
saving mode or Sabbath mode