Loading ...
Loading ...
Loading ...
en Troubleshooting
48
Error code / Fault display / Signal
Fault Cause Troubleshooting
E:2130 lights up. Intake opening of Zeolith
container is covered by
items of tableware.
Re-arrange the tableware in the ap-
pliance so the "Intake opening of
the Zeolith container " →Page16
is no longer obstructed.
E:2060 lights up. Appliance has detected cal-
cified heating element.
1. Descale the appliance.
2. Operate the appliance with the wa-
ter softening system.
1
E:3000 lights up. Water protection system is
activated.
1. Turn off the water tap.
2. Call "Customer Service"
→Page61.
E:3100 lights up. Water protection system is
activated.
1. Turn off the water tap.
2. Call "Customer Service"
→Page61.
E:3400 lights up. Water is continuously run-
ning into the appliance.
1. Turn off the water tap.
2. Call "Customer Service"
→Page61.
E:3200 or indicator for wa-
ter supply lights up.
Supply hose is kinked.
Install the supply hose without
kinks.
Water tap is turned off.
Turn on the water tap.
Water tap is jammed or
furred up.
Turn on the water tap.
The flow rate must be at least 10 l/
min when the water supply is open.
The filters in the water con-
nection of the supply or
AquaStop hose are blocked.
1. Switch off the appliance.
2. Pull out the mains plug.
3. Turn off the water tap.
4. Unscrew the water connection.
5. Remove the filter from the supply
hose
1
Depending on the appliance specifications
Loading ...
Loading ...
Loading ...