BD-S / BD-S-UL, ED-S / ED-S-UL, FD-S / FD-S-UL (E1) 10/2020 page 23/59
11.2 Setting the gradient
Simultaneously press the confirmation button and the arrow-down button to
access the “Advanced configuration” menu. The password entry display “A.Loc”
flashes.
Press the arrow-up button to access the “SPti” menu. Press the confirmation
button to select the menu.
Press the arrow-up button to access the “rAtE(ramp gradient) submenu. The
rAtE” submenu is shown with the current setting.
Press the confirmation button to activate the entry. The display “rAtEflashes.
Set the desired gradient with the arrow buttons and confirm with the confirmation
button.
Keep pressed down the confirmation button and press the arrow-up button
several times to return to Normal display.
Example:
+
20 x
5 x
or
11.3 Display of the ramp course
In normal display the target set-point and the effective ramp set-point are shown alternatingly in the lower
display.
11.4 Turning off the ramp function
To turn off the ramp function, the gradient must be set to “Off” in the “rAtE” menu (chap. 11.2).