Siemens KI81RAD30 iQ500 Built-in fridge

User Manual - Page 20

For KI81RAD30.

PDF File Manual, 86 pages, Read Online | Download pdf file

KI81RAD30 photo
Loading ...
Loading ...
Loading ...
en Installation and connection
20
Installing the appliance
Installation location
The more refrigerant an appliance
contains, the larger the room must be
in which the appliance is situated.
Leaking refrigerant can form
a flammable gas-air mixture in rooms
which are too small.
The room must be at least 1 m³ per 8 g
of refrigerant. The amount of refrigerant
in your appliance is indicated
on the rating plate inside the appliance.
The weight of the appliance may be up
to 74 kg depending on the model.
Permitted room temperature
The permitted room temperature
depends on the climatic class of the
appliance.
Information on the climatic class can be
found on the rating plate.
The appliance is fully functional within
the permitted room temperature.
If an appliance of climatic class SN is
operated at colder room temperatures,
the appliance will not be damaged up to
a room temperature of +5 °C.
Cavity depth
A cavity depth of 56 cm
is recommended for the appliance.
If the cavity depth is smaller – at least
55 cm – the energy consumption
increases slightly.
Climatic
category
Permitted room
temperature
SN +10 °C ... 32 °C
N +16 °C ... 32 °C
ST +16 °C ... 38 °C
T +16 °C ... 43 °C
Loading ...
Loading ...
Loading ...