Loading ...
Loading ...
Loading ...
Attach the Side and Top Seals
Remove the backing from the side seals and
apply to the vertical inside face edges of the
window frame and the sliding window that
will rest against the air conditioner.
On casement window installations requiring a
filler panel, one of the side seals should be
applied to the inside face edge of the filler panel
instead of to the window frame.
Peel the backing from the top seal and
apply to the top inside face edge of the
window frame.
B
A
7
Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support
Measure, Cut and Install the Filler Panel
Measure the height of the window opening
from the top of the support platform.
Subtract 20
3
4 inches. Mark this measurement
on the filler panel and cut it evenly across.
Insert the uncut end of the filler panel
into the top guide. Center the filler panel
side-to-side in the top guide.
Insert the filler panel frame over the filler
panel and into the side guides.
C
BA
Install the Guides to the Case
Install the top guide with 3 Type B screws.
Install the side guides with 3 Type B screws
on each side. Install the center screw first on
both sides.
NOTE: DO NOT drill a hole in the bottom of the pan.
The air conditioner is designed to operate with the
bottom of the pan approximately half-full of water.
B
A
5
6
Top guide
Type B screws
Type B screws
Side guide
Measure distance and
subtract 20
3
4 inches.
Top seal
11
Frame
Filler
panel
Side seals
Loading ...
Loading ...
Loading ...