- 8 -
UNPACKING AND HANDLING
1. Move the Warming Drawer as close to the point of installation as possible prior to removing packing
materials to prevent damage.
2. Remove all packing materials from inside the Warming Drawer and any protective plastic on the outside
of the Warming Drawer.
3. Read and retain all instructions before installation and use and after installation as a reference.
4. The units are heavy. Plan sufficient manpower and use caution when lifting the unit.
ELECTRICAL WIRING INSTALLATION:
WARNING:
1. All wiring must comply with all local ordinances and building codes.
2. Electrical services at the installation must meet or exceed those specified for the appliance. Do not
proceed with the installation until the specifications are met. Call a licensed electrician, if required, to
meet the necessary requirements.
3. To prevent electric shock or fire hazard, turn off power at the circuit breaker or fuse box prior to
connecting the Warming Drawer.
4. Improper connection of the electrical wiring can cause an electric shock hazard and damage the
appliance. Capital Cooking Equipment is not responsible for damages resulting from improper installation.
5. The Warming Drawer must be plugged into a grounded outlet.
6. Do not use an extension cord with this appliance. Fire, electric shock or other personal injury or damage
may occur as a result.
7. Do not install a fuse in the neutral or ground circuit. A fuse in the neutral or ground circuit may result in an
electric shock hazard.
IMPORTANT: Prior to installation and preparation of the wiring, power to the planned Warming Drawer electrical
circuit must be turned off at the breaker or fuse box.
WARNING:
Ground sources must be approved by local codes.
Electrical Requirements:
Model:
MWD301ES
Type:
Warming Drawer
Voltage:
120 VAC
Frequency:
60 Hz, Single Phase
Total Connected Load:
0.54 Kw, 4.37 Amp
Circuit Breaker Req.:
15 Amp (Dedicated)
Wire Connection:
3 Prong Plug
Electrical Requirement Summary Table