Loading ...
LOCK
Prevents activation of the garage door opener from remote controls while still
allowing activation from the door control and keyless entry. Factory default is
OFF.
Turn ON: Press and hold the LOCK button for 2 seconds. The command
LED will blink as long as the lock feature is activated.
Turn OFF: Press and hold the LOCK button again for 2 seconds. The
command LED will stop flashing and normal operation will resume.
LIGHT
Press the LIGHT button to turn the garage door opener lights on or off. The
LIGHT button will not control the lights when the door is in motion. When the
lights are turned on they will stay on until the LIGHT button is pressed again,
or until the garage door opener is activated. Once the garage door opener is
activated the lights will turn off after a specified period of time (see below).
TO CHANGE THE AMOUNT OF TIME THE GARAGE DOOR OPENER LIGHTS
WILL STAY ON
Press and hold the LOCK button until the garage door opener lights flash
(about 10 seconds). The garage door opener lights will flash up to 4 times to
indicate current setting:
1 Flash = Lights stay on 1 ½ minutes
2 Flashes = Lights stay on 2 ½ minutes
3 Flashes = Lights stay on 3 ½ minutes
4 Flashes = Lights stay on 4 ½ minutes (factory default)
Repeat the steps above until your desired time frame is reached.
LIGHT FEATURE FOR THE SAFETY REVERSING SENSORS
The garage door opener lights will turn on when the safety reversing sensor
beam is interrupted. Factory default is ON.
Turn ON: Start with the garage door opener lights on. Press and hold the
LIGHT button to turn off the light, continue to hold until the light turns on
(about 10 seconds).
Turn OFF: Start with the garage door opener lights off. Press and hold the
LIGHT button to turn on the light, continue to hold until the light turns off
(about 10 seconds).
FEATURES
TIMER-TO-CLOSE (TTC)
(for model 881LMW ONLY)
DO NOT enable TTC if operating a one-piece door. TTC is to be used ONLY
with sectional doors.
The TTC can be set to automatically close your garage door after a specified
period of time (1, 5, or 10 minute intervals). Once the TTC has been set and
the door is open, the selected close interval will blink and begin to count
down to close the door. The garage door opener will beep and the lights will
ash before closing the door.
This feature is NOT intended to be the primary method of closing the door. A
keyless entry should be installed in the event of an accidental lock out
when using this feature.
Turn ON: Press and hold the ON button until one of the TTC LEDs light up.
Change the TTC Time Intervals: Press the ON button a second time to
cycle through the time interval options (the corresponding TTC LED will
light for each time interval). The garage door opener light bulbs will blink
as confirmation.
Temporarily suspend the TTC: Press and release the HOLD OPEN button.
Press and release the HOLD OPEN button again to resume normal TTC
operation.
Turn OFF: Press and hold the OFF button until all TTC LEDs turn off and a
beep is heard from the garage door opener.
The TTC WILL NOT work under the following conditions:
If the door encounters an obstruction while closing, the garage door
opener will make a second attempt to close the door. If the obstruction
has not been cleared after the second attempt, the garage door opener will
reverse open, stop and WILL NOT close until the obstruction has been
cleared.
If the safety reversing sensors are incorrectly installed or misaligned the
garage door will reverse open and WILL NOT close until the safety
reversing sensors are correctly installed and aligned. When the safety
reversing sensors have been aligned, the door will close when the garage
door opener is activated.
If the garage door opener is operating by battery power the TTC will not
work.
NOTE: If you have an 880LMW installed and the TTC is set to a custom time,
the 3 LED's on the 881LMW will blink. If the 3 LED's are blinking and you
have an 881LMW ONLY, press the ON button to set the time properly.
MOTION SENSOR
(for models 881LMW and 886LMW ONLY)
The motion sensor will automatically turn on the garage door opener lights
when motion is detected. The lights will come on for the set period of time,
then shut off. The factory default is on for 4-1/2 minutes.
Turn ON/OFF: Slide the motion sensor switch ON or OFF.
MAINTENANCE ALERT SYSTEM (MAS)
When the garage door opener needs to be serviced (approximately 4500
garage door opener cycles) the command and service LEDs will alternately
blink back and forth. Factory default is OFF.
Turn ON/OFF: Press and hold the LEARN button. Then press the LIGHT
button. The service LED will blink the status; ON is 2 blinks and OFF is 3
blinks.
LEARN Button
LIGHT Button
Service LED
(red)
LOCK Button
Press the push bar to
open or close the door.
Motion Sensor
Motion Sensor
Switch
TTC LEDs
(1, 5, 10 Minutes)
(Model 881LMW
only)
1510
MODELS 881LMW AND 886LMW
MODEL 882LMW
LEARN Button
LIGHT Button
Service LED
(red)
LOCK Button
Command LED
(yellow)
Press the push bar to open or
close the door.
Command LED
(yellow)
ON Button
(Model 881LMW
only)
OFF Button
(Model 881LMW
only)
HOLD OPEN
(Model 881LMW
only)
NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or modifi cations of this receiver
and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE
NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards for Home or offi ce use. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
ONE YEAR LIMITED WARRANTY
LiftMaster warrants to the first consumer purchaser of this product that it
is free from defect in materials and/or workmanship for a period of 1 year
from the date of purchase.
Loading ...