Gas Connection
Hook-up to the gas supply line: 3/8” SAE (UNF 5/8” - 18) male flare connection. A
backup wrench must be used when tightening gas supply fitting. All completed
connections should be checked for leaks with a non-corrosive leak detector and/or
soap and water for a bubble check..
WARNING DO NOT USE FLAME TO CHECK FOR GAS
LEAKS
The gas supply system must incorporate a pressure regulator to maintain a supply
pressure of not more than 12” water column and no less than 11” water column. (max
setting)
Make sure the refrigerator and any other high BTU appliances on your line are turned
on when checking the gas pressure. The appliance and its individual shut-off valve
must be disconnected from the gas supply piping system during any pressure testing of
that system at pressures in excess of ½” psig.
In case detailed instructions on the installation and connection of the gas supply are
required, contact your dealer or distributor.
Leveling
Ensure the fridge is level by using a 2ft level. This is accomplished by adjusting
the feet at the front, underneath the fridge.