SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
|
11
WARNING
The accessory is factory set to use either propane (LP) or
natural gas (NAT). It is critical that the gas you use matches
that which the accessory was set up for. You can verify that
by checking the rating plate.
The rating plate is located on the heat shield behind the
front panel.
Ensure that the gas supplied meets with the minimum
pressure requirements.
Do not operate the accessory on any gas other than that for
which the accessory has been set.
Fuel WC Max Inlet WC Min Under Full
Load
Nat Gas 10 in 4 in
LP 14 in 11 in
Water Column Requirements
Both the regulator and the manifold orifices have been
tuned for the type of gas specified on the rating plate.
Converting to a different type of gas requires a conversion
kit which is included with your side burner accessory and
must be installed by a qualified technician.
All installation and all installation parts must conform to
local codes with the National Electrical Code, ANSI/NFPA
70-1990 and the National Fuel Gas Code, ANSI Z223.1/
NFPA 54 in the U.S. and CGA-B149.1/.2 in Canada.
Canadian installations must conform to CGA-B149.1/.2
natural gas/propane installation code. (Canada)
NATURAL GAS
Lynx recommends that only qualified professionals perform
the required plumbing on this product.
The gas supply line must be sized to accommodate the
total BTU requirements of all the gas-fired equipment that
will be connected to that line.
In no case should pipe less than 3/4” inside diameter or 1”
outside diameter be used.
Calculate the total BTU output of all equipment and
refer to “INDEX: Gas Supply Line Runs” for allowable run
distances. Failure to meet these minimum requirements
may reduce performance of the accessory and any other
appliances running on that supply line.
Always keep supply line runs as short as possible. (See
INDEX: “Gas Supply line runs”)
A gas shut-off valve must be installed in an easily
accessible location by a qualified plumber.
Keep any threading compound off of the first two pipe
threads to avoid having any small pieces of compound
break loose and clog a burner valve or orifice. Do not put
sealant on any male end of flare fittings.
For built-in installations, it is recommended that any flexible
pipe used be kept as short as possible. (See INDEX: “Gas
Connections” for typical permanent hook up.)
GAS PLUMBING
GAS & ELECTRIC CONNECTIONS
Keep last two
threads clean