Connection to the evacuation duct
When the cabinet is on 45 m
3
moist air/hour is
evacuated. Make sure that air can enter the room
to replace the moist air that has been ventilated.
WARNING!
The dryer cabinet must not be connected to
the duct for flue gases.
Only the supplied evacuation hose may be
used (on markets where this is supplied).
The dryer cabinet can be connected to
the evacuation duct in two ways:
With draught check
The building valve is replaced by the draught
check (supplied with the delivery).
Do not fit valves that can be found in the
property’s ventilation system inside the dryer
cabinet.
1.
Moist air out
2.
Hose.
3.
Connector
4.
Draught check
1
2
3
4
The dryer cabinet is connected to the evacuation duct with the
draught check
Permanently fitted to the evacuation duct
(only some markets)
The exhaust air duct valve must be replaced with
a transition section (not supplied).
Do not fit valves that can be found in the
property’s ventilation system inside the dryer
cabinet.
1.
Transition section
1
The dryer cabinet is permanently fitted to the evacuation duct
10
Connect to the ventilation