Rinnai EHFA250T36 250L Hotflo Electric Hot Water Storage

User Manual - Page 13

For EHFA250T36.

PDF File Manual, 20 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Rinnai 13 EHFA/EHFD HW IM
HOT WATER PLUMBING SYSTEM EXAMPLE / FLOW & RETURN PIPE WORK - NO TLD
COLD
SUPPLY
Isolating
Valve
*ECV
TO DRAIN
Non-return
Valve
*PLV
KITCHEN
LAUNDRY
NON TEMPERED SUPPLY
BATHROOM
ENSUITE
*PTR VALVE
(Supplied)
TO DRAIN
WATER
HEATER
(Not Supplied)
Non-return
Valve
Isolating
Valve
Isolating
Valve
Flow & Return
Pump
CAUTION
ValveswithpressureratingsotherthanspeciedareunsuitableandMUST NOT beused.
*
Forratingssee"Table2.Ratings&OtherSpecications"onpage11.
HOT WATER PLUMBING SYSTEM EXAMPLE / FLOW & RETURN PIPE WORK - WITH TLD
COLD
SUPPLY
Isolating
Valve
*ECV
TO DRAIN
Non-return
Valve
*PLV
KITCHEN
LAUNDRY
NON TEMPERED SUPPLY
BATHROOM
ENSUITE
TO DRAIN
*PTR VALVE
(Supplied)
WATER
HEATER
(Not Supplied)
Non-return
Valve
Non-return
Valve
Non-return
Valve
Isolating
Valve
Isolating
Valve
Flow & Return
Pump
Temperature
Limiting Device
(TLD)
CAUTION
ValveswithpressureratingsotherthanspeciedareunsuitableandMUST NOT beused.
*
Forratingssee"Table2.Ratings&OtherSpecications"onpage11.
1. Thisschematicisanexampleonly,variationsmayalsobesuitable.
2. TemperedwaterfromaTLDCANNOTbere-circulated.TheTLDMUST BE positioned in
adeadleg,branchingo󰀨thecirculatedhotwaterowandreturnpipe.
INSTALLATION
Loading ...
Loading ...
Loading ...