Rinnai EHFA250T36 250L Hotflo Electric Hot Water Storage

User Manual - Page 11

For EHFA250T36.

PDF File Manual, 20 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Rinnai 11 EHFA/EHFD HW IM
TABLE 1. DIMENSIONS & WEIGHT
Models EHFA125 EHFA160 EHFD 160 EFHA 250 EHFA 315
A 1285 1620 1313 1484 1770
B 564 564 600 674 674
C 500 500 537 605 605
D 1102 1102 1107 1248 1541
E 162 162 186 210 210
F 87 87 110 135 135
G N/A 1039 n/a 985 1225
Weight (kg) 47 59 51 71 91
All dimensions are in mm unless otherwise stated
TABLE 2. RATINGS & OTHER SPECIFICATIONS
Models EHFA125 EHFA160 EHFD 160 EFHA 250 EHFA 315
Cylinder Rated Pressure
(kPa)
1000 1000 1000 1000 1000
PTR Rated Pressure
(kPa)
1000 1000 1000 1000 1000
ECV Rated Pressure
(kPa)
850 850 850 850 850
ECV
Fitted
(kPa)
Fit PLV if mains
pressure exceeds
680 680 680 680 680
Recommended
PLV pressure rating
500 500 500 500 500
ECV
Not
Fitted
(kPa)
Fit PLV if mains
pressure exceeds
800 800 800 800 800
Recommended
PLV pressure rating
500 500 500 500 500
Rated Capacity Hot Water
Litres (l)
125 160 160 250 315
Heating Element
(W)
Lower 1800 2400 3600 1800 2400 3600 2400 3600 2400 3600 4800 3600 4800
Upper n/a n/a 3600 n/a n/a 3600 4800 3600 4800
Inlet/Outlet Connections 3/4" (20 mm)
NOTE
APLVisnotsuppliedwiththesemodels.APLVMUST BEttediftheMainsPressureexceeds
thelimitsshown.IfthemainspressureiswithinthelimitsshowntmentofthePLVisoptional.
However,itisrecommendedthatthePLVisttedinallinstallationsasitaidswaterandenergy
conservation.
A
F
G
C
B
E
D
OUTLETSP&TR
INLETS
SPECIFICATIONS
Loading ...
Loading ...
Loading ...