OPERATION
5
COOLING MODE
The compressor (6) in the external unit compresses the refrigerant into a high-temperature, high-
pressure gas. When this gas flows along the cooling fins of the condenser (7), heat is exuded and
the gas condenses into a liquid, which is then led to the evaporator (1) in the indoor unit. The
liquid expands into a gas at a low temperature and low pressure. This gas absorbs the warmth of
the air in the room, and a fan (3) draws the air through the filter and over the evaporator (1),
blowing the cooled air back into the room. The heat is moved to the compressor along with the
gas. A fan (8) draws air over the condenser and blows the warm air away.
1. Evaporator
2. Filter
4. Gas Line
5. Liquid line
7. Condenser
8. Condenser Fan
HEAT PUMP MODE
The system operates in reverse: the condenser works as an evaporator, the evaporator as a
condenser: warm air is blown into the room. It is ideal as a maintenance heating when outside
temperature is not too low and when the indoor temperature is more than 7°C.
DEHUMIDIFYING
As with cooling, the moisture in the air condenses on the cold evaporator at room
temperature acting as a powerful dehumidifier.