Audio Enabled
The audio setting for Entry Code verification is set
to enabled (1) by default; otherwise it can be set to
disabled (3) for quiet areas.
Setting Definitions
*The Master Entry Code must be created prior to any other programming of the lock.
Creation
required*
Master Entry Code
The Master Entry Code is used for programming
and feature settings. It must be created prior to
programming the lock. The Master Entry Code will also
operate (unlock/lock) the lock.
Inside Indicator Light
Disabled (Off)
Located on the inside lock. Shows active status
(Locked) of lock and can be enabled or disabled in
Advanced Lock Settings (Main Menu selection #3).
One Touch Locking
Enabled
When the latch is retracted, activating the keypad
will extend the latch (during Auto Re-lock duration
or when Auto Re-lock is disabled). When One-
Touch Re-lock is not in use (disabled), any valid
Entry Code will re-lock the lock.
All Code Lockout
Disabled
This feature is enabled by the Master Entry Code.
When enabled, it restricts all Entry Code access
(except Master). When attempting to enter a
code while the lock is in All Code Lockout, the keypad
flashes 8 times and the lock beeps 3 times as well.
Wrong Code
Entry Limit
5 Times
After five (5) unsuccessful attempts at entering a
valid Entry Code, the lock will shut down and not
allow operation for sixty (60) seconds.
Shutdown Time 60 Seconds
The lock will shutdown (flashing keypad) for sixty
(60) seconds and not allow operation after the
wrong code entry limit (5 attempts) has been met.
Settings
Default Setting
Definition
Auto Re-lock Disabled
After a successful code entry or manual unlock
with the key (YRL216), the lock will automatically re-lock
after each unlock in an effort to keep your home secure.
This feature is optional, and can be turned off.
When enabled, the lock will automatically re-lock
after thirty (30) seconds.