Loading ...
Loading ...
Loading ...
A B
50mm mini 50mm mini
Under any circumstances, make sure the ceramic cooker hob is well ventilated and
the air inlet and outlet are not blocked. Ensure the ceramic cooker hob is in good
work state. As shown below
Note: The safety distance between the hotplate and the cupboard above the
hotplate should be at least 760mm.
wall
Min.30mm
760 mm
A (mm) B (mm) C (mm) D E
760 50 mini 20 mini Air intake Airexit5mm
WARNING: Ensuring Adequate Ventilation
Make sure the ceramic hob is well ventilated and that air inlet and outlet are not
blocked. In order to avoid accidental touch with the overheating bottom of the hob,
orgettingunexpectableelectricshockduringworking,itisnecessarytoputawooden
insert,xedbyscrews,ataminimumdistanceof50mmfromthebottomofthehob.
Follow the requirements below.
Max. 5 mm Max. 5 mm
Min. 50 mm
EN-19
Loading ...
Loading ...
Loading ...