Installation Instructions
4
ELECTRICAL REQUIREMENTS
(Cont.)
This appliance must be supplied with the proper voltage
and frequency and connected to an individual, properly
grounded branch circuit, protected by a circuit breaker or
fuse. See the rating plate located on the underside of the
control panel to determine the rating of the product.
Use the chart below to determine the minimum
recommended dedicated circuit protection:
DO NOT shorten the flexible conduit. The conduit strain
relief clamp must be securely attached to the junction
box and the flexible conduit must be securely attached
to the clamp. If the flexible conduit will not fit within the
clamp, do not install the oven until a clamp of the proper
size is obtained.
The 3 power leads supplied with this appliance are
suitable for connection to heavier gauge household
wiring. The insulation of these 3 leads is rated for
temperatures much higher than the temperature rating
of the household wiring. The current-carrying capacity
of the conductor is governed by the wire gauge and the
temperature rating of the insulation around the wire.
5
MAKE ELECTRICAL
CONNECTIONS
WARNING
Switch power off at the service panel
and lock the service disconnecting means to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as
a tag, to the service panel.
Place oven on table or platform even with the cutout
opening. For a steam oven, the platform must
support 170 lbs. (78 kg). Connect the flexible conduit
to the electrical junction box as shown below*.
Position the conduit in such a manner that it will lie
behind the unit in a natural loop when the oven is
installed. You will need to purchase an appropriate
strain relief clamp to complete the connection of the
conduit to the junction box.
* Ovens come equipped with a 40” or 54” long conduit.
If a longer conduit is desired, there may be one
available for your model. To check availability or
order parts, visit monogram.com.
KW Rating
240V
KW Rating
208V
Recommended
Circuit Size
(Dedicated)
≤4.8 KW ≤4.1 KW 20 Amp
4.9 KW–7.2 KW 4.2 KW–6.2 KW 30 Amp
7.3 KW–9.6 KW 6.3 KW–8.3 KW 40 Amp
9.7 KW–12.0 KW 8.4 KW–10.4 KW 50 Amp
Rating plate is located on the underside
of the control panel
Rating Plate
Location
Junction Box
Conduit
Ground
Red
White
Black
Strain Relief Clamp
(not included) Must Be
Used at Junction Box
Place Oven on a
Support to Assist in
Connecting Conduit
Ground
Wire