TROUBLESHOOTING
Problem: Temperature does not change at programmed start time for a given period
Solution:
1. Verify that the HOLD feature is not active (see “Overriding the Schedules Permanently,”
page 27).
2. Check the programmed schedule (see “Modifying the Programmed Schedule,” page 24).
3. Verify that the thermostat is not in MANUAL mode (see “Turning Off Schedules,” page 28).
Problem: Heat/cool system doesnt respond immediately
Solution:
1. To protect your compressor, the thermostat default is to wait five minutes before responding.
(see “Minimum Cycle Period Adjustment,” page 18).
2. If the problem persists aer waiting five minutes, check baeries.
Replace if necessary (see “Replacing the Baeries,” page 31).
TROUBLESHOOTING
Problem:
Set temperature is 10°F above (in cool mode) or 10°F below (in heat mode) desired temperature
Solution: Check baeries. Replace if necessary (see “Replacing the Baeries,” page 31).
Problem: System turns on too frequently
Solution: The Orbit Clear Comfort™ Pro thermostat uses smart logic to turn on once every
cycle period to maximize comfort and temperature stability. To adjust the cycle period, see
“Minimum Cycle Period Adjustment,” page 18. To turn off smart logic, set the cycle period back
to the default seing of 0.
Problem: Display is blank/Low Baery Indicator on
Solution:
1. Replace baeries (see “Replacing the Baeries,” page 31).
2. Check for loose or crossed wiring in thermostat wiring terminal.
Downloaded from www.ManualsFile.com manuals search engine