PWM 908 en-GB
= standard, = optional, + = only on request, - not available
11 276 340/05 11
Technical data
PWM 908 DV
PWM 908 DP
Drain pump (DP)
Hose connection (external diameter)
mm
-
22 (DN 22)
Max. drainage temperature
°C
-
90
On-site hose sleeve (int. diameter x length)
mm
-
22 x 30
Max. transient flow rate
l/min
-
26
Max. delivery head (from lower edge of machine)
mm
-
1000
Drain hose DN 22 with connector (supplied as standard)
-
Connection hose length
mm
-
1500
Equipotential bonding (PA)
Machine connection (separate kit required)
XCI box LG interface
Peak load/energy management (SLA)
Machine connection (with XCI box LG)
Payment system connection (KGA)
Connection of payment systems (with XCI box LG)
Communication module (XKM)
Communication module XKM 3200 WL PLT
Liquid dispensing (DOS)
Connection for liquid detergents
Max. no. of dispenser pumps
No.
6
6
XCI box LG interface
Installation on machine feet (F)
No. of machine feet
No.
4
4
Machine foot, height-adjustable with thread
mm
+8
+8
Diameter of machine feet
mm
40
40
Anchoring (B)
Standard anchoring
Floor anchor kit (for 2 machine feet) with anchors
Wood screws according to DIN 571
mm
6 x 50
6 x 50
Rawl plugs (diameter x length)
mm
8 x 40
8 x 40
Anchoring of Miele plinths
Accessory: Miele plinth (fasteners included)
Required anchor points
No.
4
4
Wood screws according to DIN 571
mm
8 x 65
8 x 65
Rawl plugs (diameter x length)
mm
12 x 60
12 x 60
Plinth floor anchoring (to be provided on site)
Machine installation on permanent plinth (concrete or masonry)
Plinth installation footprint (W/D)
mm
600/650
600/650
Wood screws according to DIN 571
mm
6 x 50
6 x 50
Rawl plugs (diameter x length)
mm
8 x 40
8 x 40