Vacation and Extended Shut-Down
If the water heater is to remain idle for an
extended period of time, the power and
water to the appliance should be turned
off to conserve energy and prevent a build-
up of dangerous hydrogen gas.
The water heater and piping should be
drained if they might be subjected to
freezing temperatures.
After a long shut-down period, the water
heater’s operation and controls should
be checked by qualified service personnel.
Make certain the water heater is
completely filled again before placing it
in operation.
NOTICE: Refer to
the Hydrogen Gas
Caution in the Operating
Instructions.
Anode Rod
This water heater is equipped with an
anode rod designed to prolong the life
of the glass lined tank. The anode rod is
slowly consumed, thereby eliminating or
minimizing corrosion of the glass lined
tank.
Water sometimes contains a high sulfate
and/or mineral content and together with
cathodic protection process can produce
a hydrogen sulfide, or rotten egg odor
in the heated water. Chlorination of the
water supply should minimize the problem.
NOTICE: Do not remove
the anode rod from the
water heater’s tank,
except for inspection
and/or replacement, as
operation with the anode
rod removed will greatly
shorten the life of the
glass lined tank and
will exclude warranty
coverage.