27
Venting System Inspection
The water heater’s internal flue must be
inspected annually to be certain it is clean
by removing the blower assembly and flue
baffle.
When reinstalling the flue baffle make
certain it is hung securely by its hanger
at the top of the flue way.
Reinstall the blower assembly.
Inspect the gas venting system and the
chimney.
Make certain the vent connector from the
blower assembly to the chimney is properly
positioned and securely attached.
If after inspection of the vent system
you found soot or deterioration;
call the local gas utility to correct the
problem and clean the flue, or replace the
flue, flue baffle, and venting system before
resuming operation of the water heater.
Test for spillage at the blower assembly
relief opening after 5 minutes of burner
operation. Use a flame of a match or
candle or smoke.
Housekeeping
Visually inspect hot surface ignitor.
To ensure sufficient ventilation and
combustion air supply, proper clearances
must be maintained.
When installed in a closet, DO NOT
block or obstruct any of the combustion
air inlet openings located around
the perimeter of the water heater. A
minimum of 1” is required between
these combustion air inlet openings
and any obstruction.
DO NOT obstruct or block the
Flammable Vapor Sensor. The sensor
does not require any maintenance or
cleaning. DO NOT expose to cleaning
agents.
!
DANGER: Combustible
materials, such as
clothing, cleaning
materials, or flammable
liquids, etc., must not be
placed against or next to
the water heater.
Burner Inspection
Visually inspect the hot surface ignitor
and main burners annually.
Through the sight glass, inspect the hot
surface ignitor with the main burner off
and inspect the main burner while firing.
If any unusual burner operation is noted,
the water heater should be shut off
until qualified service assistance can be
obtained.
!
CAUTION: For your safety,
cleaning of the burner must be
performed only by qualified service
personnel, as it involves the
disconnection of gas piping and
leak testing.. The burner chamber
is a sealed area. If the burner
access door is removed, the burner
access door gasket must be
replaced.
For cleaning, remove the burner from the
water heater. A vacuum cleaner can be
used on the burner and floor shield inside
the water heater.The burner can also be
cleaned by scrubbing with mild detergent.
Proper burner flame pattern.