Adjustments:
If there was a problem during Initial Start
Up:
If an error light came on, check the following.
1. Water error.
A water error could have been determined by the
System Controller if the inlet water valve does not
fill the reservoir, or if the water pump does not start
and lower the water level.
2. Refrigeration error.
A refrigeration error could have been determined
by the System Controller if the water temperature
did not drop during the freeze cycle. The controller
will next check the compressor discharge
temperature, If the discharge temperature is too
low, the refrigerant error light will be switched on,
and the machine will Shut Down.
Note: Reset and restart the machine by pushing
and releasing the Off push button switch, and then
pushing and releasing the freeze push button
switch.
How to Adjust the Amount of Water Purge
Adjustment is done by use of the control buttons
on the AutoIQ Controller. Examine the next section
to become familiar with the Controller before
beginning.
1. If the machine is on, push and hold the OFF
button for more than 3 seconds, then release it.
This switches the machine Off.
2. Push and hold the OFF button for more than 3
seconds (just until all lights flash on) then release
it. Do not hold it in it too long.
3. Examine the green lights. They should have all
flashed once, then certain ones will have turned on
to indicate which purge level the machine is set at.
There are 5 levels of purge available:
1. Maximum Purge is when All 5 lights are
ON. Use for extreme water conditions. Note:
This setting may extend the Harvest cycle
and reduce capacity.
2. Heavy Purge is when these 4 lights are
ON: Freeze
, Harvest, Clean,Off. Use for
severe water conditions.
3. Standard Purge (factory setting) is when
these 3 lights are ON: Harvest
, Clean,Off.
Use for moderate to severe water
conditions.
4. Moderate Purge is when these 2 lights
are ON: Clean
,Off. This is for typical water
conditions.
5. Minimum Purge is when this light is ON:
Off
. For excellent water conditions.
Adjust by pushing and releasing the Freeze
button. Pushing and releasing the Freeze button
increases the purge one level up to the maximum,
then it goes to the minimum.
4. The machine will automatically restart after 60
seconds of no switch inputs, or restart the machine
by pushing in and holding the Off button for more
than 3 seconds, then releasing it. The unit will then
be Off. From there the machine may be placed in
a freeze cycle by pushing and releasing the
Freeze button.