GAS INSTALLATION
GAS TYPE
The Capital range of upright cookers comes pres et for either LP G(2 .75kPa) or Natural Gas (1.0 kP a). Pleas e refer
to the data plate for details of burner jet sizes and gas consumption. It is imperative that you confirm the gas type
available to the location prior to installing. Allowing the cooker to be connected to the wrong gas type can cause a
serious f ire and/or health hazard.
GAS INLET CONNECTION
Fit the supplied regulator (if applicable) at the rear of appliance, and as close as practicable to the appliance. Note
that the inlet connection points to the right, when looking at the rear of the unit.
It is recommended that an isolating valve and union be fitted, to enable simple disconnection for servicing. These
are to be in an accessible location.
FLEXIBLE HOSE
If a flexible hose is us ed,it should be as short as possible with a maximum length of 1.5 metres ;
o The f lexible connection must be approved to class B or D of AS/NZS1869 as a minimum.
o it should not be bent, kinked or compressed;
o it should not be in contact with the rear wall of the appliance or in any cas e with parts which may
reach a temperature of 50°C;
o it should not come into contact with pointed parts or sharp corners ;
o it should not be subject to any pulling or twisting forces;
o it should be easy to inspect along its entire length in order to be able to check its condition.
o The supply connection point must be accessible with the appliance installed.
o The inner diameters of the pipe are as follows :
8mm for LPG;
13mm for Natural Gas .
ANTI-TILT DEVICE
It is a requirement that the anti-tilt brackets must be installed to prevent inadvertent tipping of the appliance.