HE240, HE280 HUMIDIFIER AND INSTALLATION KIT
19 69-2685ES—01
Low
humidity
Furnace blower
not operating.
Reset circuit breaker or check for blown fuse.
Check that the furnace power is on.
Check all external wiring connections.
Check the humidity control setting.
Verify that pressure switch tubing isn't pinched
or obstructed.
Call a professional heating contractor.
Rapid air changes.
Drafts (cold air is
dry and is an
added load to the
humidifier).
Keep doors and windows closed.
Close fireplace damper when not in use.
Keep exhaust fan running time to a minimum.
Seal around doors and windows.
Damper in
“summer” position
Set damper blade to "winter" position to allow
humidification.
High
humidity
Condensation on
walls.
Turn off humidity control and water until
condensation is completely evaporated.
Heavy
condensation on
windows.
Turn humidity control down low enough to
eliminate condensation caused by moisture
from bathing, mopping, cooking, etc. If
moisture persists, more ventilation is needed.
Table 4. Troubleshooting Humidifier. (Continued)