Candy PL 40 W Hobs

User Manual - Page 54

For PL 40 W.

PDF File Manual, 102 pages, Download pdf file

Loading ...
Loading ...
Loading ...
For models fitted with ignition switch, turn the gas tap knob to the maximum delivery position, then
press the ignition switch and the knob, holding down for about 4÷5 seconds. Then release the knob
and adjust the flame by turning the knob to the desired intensity.
) 'Warning':
The ignition device must not be used for more than 15 seconds.
If after this length of time the burner does not light, or if it goes out again accidentally, wait
1 minute before trying to ignite the burner again.
Choosing the right burner
The symbols stamped on the control panel (fig. 4) next to the knobs indicate which knob corresponds
to which burner. To choose the most suitable burner, take into account the diameter of the pan as well
as the pan capacity (see table).
The diameter of the pan must be proportionate to the burner power in order to ensure high yield.
ADJUSTMENT TO DIFFERENT TYPES OF GAS
If a different type of gas from the one indicated on the rating plate is used, the injectors must be
replaced.
If spare injectors are not supplied with the appliance, they are available from the After-sales service.
For the choice of replacement injectors, refer to the injectors table.
The injectors are identified by their diameter, which is expressed in hundredths of mm, stamped on the
body of the injector itself.
Replacing the injectors
Remove the grids and burner caps from the cooktop
Using a socket wrench, replace the injectors “J” (fig. 11) with the suitable ones for the gas used.
Replace the burners ( see fig. 13 )
The burners do non require primary air adjustment.
Adjustment of minimum setting
After replacing the injectors, light the burner and remove the knob. Turn the tap to the minimum setting
and insert a screwdriver in the rod: tighten to reduce the flame, loosen to increase the flame. (fig. 11)
For gas G30/G31, tighten the adjustment screw fully
The flame must be small, uniform and regular all around the burner crown.
Finally, check that the flame does not go out by rapidly turning the tap from the maximum setting to
the minimum. For burners with a safety device, check that the flame slightly licks the thermocouple.
Make sure that the adjustment is correct by leaving the burner alight for a few minutes. If it goes out,
increase the minimum setting.
Pan diameter
Burner Minimum diameter Maximum diameter
Auxiliary
60 mm (with reducer)
140 mm
Semirapid 160 mm 200 mm
Rapid 200 mm 240 mm
52
Loading ...
Loading ...
Loading ...