Elica EPR628S1 28 Inch Cabinet Insert Range Hood with 3-Speed/600 CFM Blower, Push Button Controls, LED Lighting

Installation Instructions Guide - Page 8

For EPR628S1. Series: Elica Palermo Series
Also, The document are for others Elica models: EPR628SS, EAS428SS

PDF File Manual, 36 pages, Read Online | Download pdf file

EPR628S1 photo
Loading ...
Loading ...
Loading ...
8
Venting Outside Through the Roof
1. Measure and mark the lines as shown. Use a saber saw or
keyhole saw to cut an opening through the top of the cabinet
and the roof for the vent.
A
B*
C
D
A. Cutout
B.6¼”(15.9cm)*
C. 7¾”(19.7cm)centerlinetocabinetfront
D. Centerline
*NOTE:For12”(30.5cm)highcabinetsa6¼”deepx8”wide
(14.6cmx20.3cm)rectangularopeninginthecabinettopis
required for damper transition clearance.
Venting Outside Through the Wall
1. Installthe6”(15.2cm)venttransitiontothetopoftherange
hood liner using two 3.5 x 9.5 mm screws. Assemble the vent
ductthatyouwilluseoverthe6”(15.2cm)venttransition.
2. Measure from the bottom of the range hood liner to the
horizontalcenterlineoftheventopening(A)
A
B
C
A. Measurement A
B. Horizontal centerline of vent opening
C. Range hood liner
3. Remove the vent duct from the range hood liner.
Transfer measurement A to the cabinet back wall. Measure
from the underside of the cabinet.
4. Mark the cutout as shown. Use a saber saw or keyhole saw to
cut a round opening through the back of the cabinet and the
exterior wall for the vent. Go to Step 3.
A
B
C
A. Measurement A
B. Centerline
C.6¼”(15.9cm)round
cutout
Non-Vented (recirculating) Installation Through the
Soft/Cabinet
E
A
B
G
D
F
H
I
A
B
G
F
C
D
E
A. Ceiling
B. Vent cover
C. Soffit
D.6”(15.2cm)vent
E. Range hood
F. Cabinet
G.Wall
H.12”(30.5cm)min.cabinetheight
I.17”(43.2cm)min.ventcoverheight
1. Measureandmarkthecenterlineofthecabinettothesoft
above.
2. Measure from the bottom of the cabinet to the centerline of
thewheretheventwillcomethroughthesoft.Markthe
location and use a saber saw or keyhole saw to cut a 5¾”
(14.6cm)holefortheventcover.
A
B
A. Vent cover
B. Centerline
*NOTE:For12”(30.5cm)highcabinetsa6¼”deepx8”wide
(14.6cmx20.3cm)rectangularopeninginthecabinettopis
required for damper transition clearance.
Measure and mark the centerline location for the cutout in the
cabinet top. Use a saber saw or keyhole saw to cut an
opening for the vent.