6 | Sub-Zero Customer Care 800.222.7820
Plumbing Requirements
Installation must comply with all applicable plumbing codes.
Locate the water supply line within the shaded area shown
in the illustration below. Connect the water supply line to the
house supply with an easily accessible shut-off valve. Do
not use self-piercing valves. The water supply line must be
ush with the oor and cannot interfere with the installation
of the anti-tip bracket.
Column and tall models with an ice maker or water dis-
penser feature a water ltration system. An in-line lter is
required for drawer models with an ice maker when water
conditions have a high sediment content.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
(2.4–8.3 bar) supplied
to the unit at all times. In this application, the water ltra-
tion system must be bypassed. Refer to Water Filter Bypass
on page 18. A copper line is not recommended for this
application.
WATER SUPPLY LOCATION
A
18" Model 3" (76)
24" Model 5
1
/2" (140)
30" Model 6" (152)
36" Model 9" (229)
3" (76)
6" (152)
RIGHT SIDE
OF OPENING
AREA EXTENDS
1
/2" (13)
FORWARD ON FLOOR
A
Water supply location
SITE PREPARATION
PLUMBING REQUIREMENTS
Water Supply Line
1
/4" OD copper, braided
stainless steel, or PEX tubing
Water Pressure 35–120 psi (2.4–8.3 bar)
Excess Water Line for Connection 36" (914)