GAS VALVE LED STATUS/PROBLEM PROBABLE CAUSE SOLUTION
Six-Four Flashes,
three second pause
System in Lockout/
Flame sense out of
sequence
Gas Control (Thermostat's) valve
stuck open
Replace Gas Control (Thermostat)
Seven Flashes, three
second pause
System in Lockout/
Presence of Flamma-
ble Vapors detected
Gasoline or other ammable
vapor(s) were detected
Faulty Flammable Vapor Sensor
Faulty Gas Control (Thermo-
stat)
Ensure that no ammable vapor(s)
are present
Reset the Gas Control (Thermostat)
using "ON/OFF" switch located on
the front of the control
Replace Flammable Vapor Sensor
Replace Gas Control (Thermostat)
Eight-One Flash,
three second pause
System in Lockout/
Flammable Vapor
Sensor fault detected
Flammable vapor sensor values
out of range
Improper Flammable Va-
por Sensor wiring and/or
connection(s)
Faulty Flammable Vapor Sensor
Inspect the Flammable Vapor Sen-
sor wiring and connection(s)
Replace Flammable Vapor Sensor
Replace Gas Control (Thermostat)
Eight-Two Flashes,
three second pause
System in Lockout/
Energy cutoff device
fault detected
Thermal well fault in Gas Con-
trol (Thermostat)
Inspect the wiring connection(s) to
the thermal well
Replace the thermal well
Eight-Three Flashes,
three second pause
System in Lockout/
Fault in the electronics
circuit detected
Thermal well fault in Gas Con-
trol (Thermostat)
Faulty Gas Control (Thermo-
stat)
Replace thermal well
Replace Gas Control (Thermostat)
Eight-Four Flashes,
three second pause
System in Lockout/
Fault with the Gas
Control (Thermostat)
Gas Control (Thermostat) needs
to be reset
Gas Control (Thermostat) has
been damaged
Cycle the power to the Gas Control
(Thermostat)
Replace the Gas Control (Thermo-
stat)
Gas Valve LED Codes cont.....
25
CAUTION: Make certain power to water heater is “OFF” before removing protective cover FOR ANY REASON.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation. VERIFY PROPER OPERATION AFTER SERVICING.
CAUTION: For your safety DO NOT attempt repair of gas piping, remote control, burners, vent connectors or other
safety devices. Refer repairs to qualified service personnel.
Loading ...
Loading ...
Loading ...