Baumatic BHG300.5SS Hobs

User Manual - Page 11

For BHG300.5SS.

PDF File Manual, 20 pages, Read Online | Download pdf file

BHG300.5SS photo
Loading ...
Loading ...
Loading ...
10) REPLACING THE INJECTORS
The burners can be adapted to different types of
gas by mounting injectors suited to the type of gas
in question. To do this, first remove the burner tops
using a wrench “B”. Now unscrew injector “A” (see
fig. 13) and fit a injector corresponding to the
utilised type of gas in its place.
I
t is advisable to strongly tighten the injector in
place.
After the injectors have been replaced, the
burners must be regulated as explained in
paragraphs 9. The technician must reset any
seals on the regulating or pre-regulating devices.
The envelope with the injectors and the labels can
be included in the kit, or at disposal to the
authorized customer Service Centre.
For the sake of convenience, the nominal rate table
also lists the heat inputs of the burners, the
diameter of the injectors and the working pressures
of the various types of gas.
BURNER ARRANGEMENT ON THE HOB
CONVERSIONS
FIG. 13
10
BURNERS
GAS
NORMAL
PRESSURE
mbar
NORMAL
RATE
INJECTOR
DIAMETER
1/100 mm
NOMINAL HEAT
INPUT (W)
DESCRIPTION
g/h l/h Min. Max.
2
R
A
PID
G30 - BUTANE
G31 - PROPANE
G20 - NATURAL
28 - 30
37
20
218
214
286
85
85
115 Y
800
800
800
3000
3000
3000
3
AUXILIARY
G30 - BUTANE
G31 - PROPANE
G20 - NATURAL
28 - 30
37
20
73
71
95
50
50
72 X
400
400
400
1000
1000
1000
3
Loading ...
Loading ...
Loading ...