DUCT EQUIVALENT NUMBER
PIECES LENGTH x USED = TOTAL
3¼” x 10” 1 Ft. x ( ) = Ft.
Rect.,
straight
7” Round, 1 Ft. x ( ) = Ft.
straight
6” Round, 1 Ft. x ( ) = Ft.
straight
3¼” x 10” 8.5 Ft. x ( ) = Ft.
Rect. 90°
elbow
3¼” x 10” 7 Ft. x ( ) = Ft.
Rect. 45°
elbow
3¼” x 10” 24 Ft. x ( ) = Ft.
Rect. 90°
flat elbow
3¼” x 10” 45 Ft. x ( ) = Ft.
Rect.
(7 ft. w/o
wall cap
damper)
x ( ) = Ft.
with
damper
3¼” x 10” 4.5 Ft. x ( ) = Ft.
Rect. to
6” round
transition
3¼” x 10” 11.5 Ft. x ( ) = Ft.
Rect. to
6” round
transition
90° elbow
6” Round, 8 Ft. x ( ) = Ft.
90° elbow
6” Round, 6.5 Ft. x ( ) = Ft.
45° elbow
Subtotal column 1 = Ft.
7
WORKSHEET—CALCULATE TOTAL EQUIVALENT DUCTWORK LENGTH
DUCT EQUIVALENT NUMBER
PIECES LENGTH x USED = TOTAL
6” Round 34 Ft. x ( ) = Ft.
wall cap
(6 ft. w/o
with
damper)
x ( ) = Ft.
damper
6” Round 30 Ft. x ( ) = Ft.
roof cap
6” Round 5.5 Ft. x ( ) = Ft.
to
3¼” x 10”
rect.
transition
6” Round 14.5 Ft. x ( ) = Ft.
to
3¼” x 10”
rect.
transition
90° elbow
7” Round, 8 Ft. x ( ) = Ft.
90° elbow
7” Round, 6.5 Ft. x ( ) = Ft.
45° elbow
7” Round 34 Ft. x ( ) = Ft.
wall cap (
6 ft. w/o
with
damper)
x ( ) = Ft.
damper
7” Round 30 Ft. x ( ) = Ft.
roof cap
7” Round 5.5 Ft. x ( ) = Ft.
to
3¼” x 10”
rect.
transition
7” Round 14.5 Ft. x ( ) = Ft.
to
3¼” x 10”
rect.
transition,
90° elbow
Subtotal column 2 = Ft.
Subtotal column 1 = Ft.
Total ductwork =
Ft.
Installation Instructions
MAXIMUM DUCT LENGTH: For satisfactory air
movement, the total duct length of a 3¼” x 10”
rectangular, 6” or 7” diameter round duct should
not exceed 65 equivalent feet.
1 Ft = 0.3 m