Loading ...
Loading ...
Loading ...
13 | P a g e
SETTING SWITCH OFF TIMER
With the air conditioner operating in any function mode, press the Timer Control button. Then set
the desired time delay OFF hours by pressing the + or - buttons. When the delay time set has
elapsed, the air conditioner switches off.
SETTING DELAYED SWITCH ON TIMER
With the air conditioner is off, press the Timer Control button. Then set the desired time delay ON
hours by pressing the + or - buttons. When the delay time set has elapsed, the air conditioner
switches on.
AUTO RESTART
In the event of a power outage, the air conditioner restarts at the previously set function mode and
settings when power is restored.
NOISE LEVEL
Portable air conditioners may make sounds that are not familiar to you. The sounds listed below are
normal. Noise reflecting off hard surfaces such as a floor or wall can make the sounds seem louder
than they actually are.
The compressor may make a pulsating or high-pitched sound.
Water running from the evaporator to the water tank may make a splashing sound.
Refrigerant flowing may make a gurgling sound.
Fan sound may come from front and back air vents.
Continuous Gravity Drainage Option:
This option is recommended if uninterrupted operation is desired.
1. Remove the drain plug cover and rubber plug from the upper drain port.
2. Install the drain hose (sold separately) through the drain cover.
3. Thread the drain cover onto the upper drain port.
4. Place the open end of the drain hose downward to an area appropriate for draining.
COMPRESSOR LOCK OUT
This portable air conditioner is optimized to operate in an ambient temperature of 64°F – 90°F. The
compressor circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly.
This prevents over-heating of the compressor and possible circuit breaker tripping.
WATER DRAINAGE
The air conditioner has the capacity to dehumidify up to 96 pints per day. The patented self-
evaporating function of the unit fully exhausts all condensation automatically in most environments
when humidity is less than 70%. Areas with more than 70% humidity, the self-evaporating function can
still exhaust about 98% of the moisture and the remaining 2% of moisture will be collected in the water
tank of the air conditioner. When there is excess water condensation inside the unit, the air conditioner
stops running and the RED Stop light illuminates. The Stop light indicates that the water condensation
needs to be drained manually:
Manual Drain:
1. Turn off the unit.
2. Carefully roll the unit to a drain location or position a flat container, dish or optional drain bucket
accessory (sold separately) under the drain area of the lower drain port.
3. Remove the drain cover and rubber plug and the condensed water will drain out automatically.
4. Once all the condensed water is drained, replace the drain rubber plug and cover into the drain
firmly.
Loading ...
Loading ...
Loading ...