12 | P a g e
OPERATION INSTRUCTIONS
BEFORE USING YOUR PORTABLE AIR CONDITIONER
Remove the exterior and interior packaging.
Before connecting the unit to the power source, let it stand upright for a minimum of 4 hours.
This will reduce the possibility of a malfunction in the cooling system from handling during
transportation.
SWITCHING ON/OFF THE AIR CONDITIONER
The unit can be switched ON or OFF by pressing the Power button on the control panel or
the Power button on the remote control.
COOLING MODE
In this mode, the air conditioner cools and dehumidifies the room. To activate the cooling
function, press the Mode Control button until the GREEN indicator illuminates. When cooling
mode is set, the compressor will start in approximately 3 minutes.
NOTE: In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust
hose must be connected to exhaust out the hot air.
The temperature setting range of this air conditioner is from 61°F to 89°F. To set the
temperature, press the + or - buttons. This air conditioner has a 5°F temperature cushion; if the
set temperature is within 5°F of the ambient temperature, the unit runs in fan only mode. This
saves energy and prolongs the life of the compressor of the air conditioner. Once the set
temperature is achieved, the compressor will turn off and the fan runs continuously to circulate
the air within the room.
To set the fan speed, press the Fan Speed button.
Note: When the compressor is running, the sound difference between each fan speed is not
very noticeable.
DEHUMIDIFYING MODE
In this mode, the air conditioner dehumidifies the room, the compressor will activate intermittently
depending on the ambient temperature and the fan speed is set to Low.
To activate dehumidifying mode, press the Mode Control button until the PURPLE indicator illuminates.
When switching between functions, there will be an approximate 3 minute transition time.
In dehumidifying mode, the exhaust hose does not need to be vented. If the exhaust hose is vented, the
room will be cooled as it dehumidifies. To prevent cooling, remove the exhaust hose from the window kit
and allow the warm air from the rear to be re-circulated into the room. If room temperature is higher than
77°F, the fan speed can be adjusted. If room temperature is lower than 77°F, the fan speed is set at Low.
NOTE:
When using dehumidifying mode, venting the exhaust hose to the outside is not required. If vented, the
warm air is exhausted to the outside and cooling within the room may occur. Additionally, if the exhaust
hose is not vented, the unit may require more frequent draining.
The air conditioner does not have a humidistat in which a specific humidity level can be set.
FAN ONLY MODE
In this mode, only the fan of the air conditioner runs and circulates the air within the
room. To activate fan only mode, press the Mode Control button until the YELLOW
indicator illuminates. In this mode, the temperature cannot be set. Subsequently, set the
desired fan speed by pressing the Fan Speed button.
Note: When using fan only mode, venting the exhaust hose to the outside is not
required.
TIMER (DELAYED SWITCH ON / OFF) FUNCTION
This function mode enables a delayed switch ON or delayed switch OFF of the air
conditioner. The time (hours) delay can be set, enabled and disabled. The timer is
adjustable between 1-24 hours.