Fault Possible cause Remedial action
Appliance is not cooling,
temperature display and light
are lit.
Showroom mode is
switched on.
Hold down alarm button, Fig $/11, for
10 seconds until an acknowledgement signal
sounds.
After a short time check whether your
appliance is cooling.
The side panels of the
appliance are warm.
Pipes run into the side panels
which heat during the
cooling process.
That is normal behaviour for the appliance and
not a fault.
Furniture touching the appliance will not be
damaged by the heat.
Freezer compartment door
was open for a long time;
temperature is no longer
reached.
The evaporator (refrigeration
generator) in the
NoFrost system is covered
in thick ice and can no
longer be defrosted fully
automatically.
To defrost the evaporator, remove the frozen
food with the compartments, insulate well
and store in a cool location.
Switch off the appliance and move it away
from the wall. Leave the appliance door open.
After approx. 20 min. the condensation begins
to run into the evaporation pan, at the rear of
the appliance.
To prevent the evaporation pan from
overflowing in this case, mop up the
condensation with a sponge.
The evaporator is defrosted when the water
stops running into the evaporation pan. Clean
the interior. Switch the appliance back on
again.
Automatic super freezing
does not switch on.
The appliance decides independently whether
automatic Super freezing is required and
automatically switches it on or off.