4 Care and maintenance
4.3 Long-life-Plus activated charcoal filter
The long-life-Plus activated charcoal filter should be cleaned and regenerated every 3 to
6 months with normal use and whenever the saturation indicator alarm is triggered. De-
pending on intensity of use, do not exceed 5–8 regeneration cycles. If properly cared for,
the service life of the long-life-Plus activated charcoal filter is up to three years.
Switch off the power supply to the appliance.
Removing
3
200°C
1h
2
1
Remove the metal grease filters.
Using the handle , remove the activated charcoal filter unit down and out of the
guide rail.
Cleaning and regenerating
Heat the activated charcoal filter unit in the oven .
Select top/bottom heat or hot air at 200 °C and regenerate on the wire shelf for 60
minutes.
Allow to cool down.
After heat regeneration in the oven, allow the activated charcoal filter to cool down
before putting it back in the range hood. Risk of burns!
Reassemble in the reverse order.
Reset saturation indicator alarm (see page 18).
Dispose of the spent long-life-Plus activated charcoal filter at a suitable recycling
point.