Adapting the hob to different types of gas
To adapt the Hob for use with different types of gas, carry out the following instructions:
remove the grids and burners
insert the hexagonal spanner (supplied) into the burner support (Fig. 5)
unscrew the injector and replace it with one suitable for the gas to be used (see
Table of gas consumption)
carry out regulation of the burner.
Hexagonal spanner
Fig. 5
Regulating the burners
For maximum efficiency from the burners, the correct combustion of the flame is neces-
sary (see table of gas consumptions quota “X”). A good flame must be well aligned and
without yellow tips (Fig. 7/B). If there is insufficient air, the flame will be uneven with yel-
low tips (Fig. 7/A). If there is too much air, the flame will be very short and bright (Fig.
7/C). In these cases the combustion
must be adjusted by re-fitting the carburation tube to the Venturi (where there is insuffi-
cient air) or removing the carburation tube (in the case of too much air). To position the
carburation tube, the fixing screws must be loosened, and retightened when the sati-
sfactory combustion is obtained.
air
regul.
4 mm
4 mm
2 mm
6 mm
15 mm
13 mm
Working
burner
large back right
large front left
medium
small
double ring
maxi
Ø injector
1/100 mm
120
127
93
80
2x94
2x94
Ø injector
1/100 mm
80
84
61
54
2x65
2x65
Qn
kW
2,65
2,95
1,5
1,1
3,3
3,3
l/h
G20
252
281
143
105
314
314
g/h
G30
193
215
109
80
238
238
g/h
G31
189
211
107
79
236
236
Qn
kW
2,5
2,8
1,45
1,05
3,1
3,1
l/h
G25
277
310
161
116
314
314
Qmin.
kW
0,650
0,650
0,380
0,280
0,900
0,900
air
regul.
4 mm
4 mm
2 mm
6 mm
13 mm
13 mm
air
regul.
2 mm
2 mm
5 mm
4 mm
0 mm
0 mm
G20 G30 G25 G31
G30G20/G25 G20/G30 G25
Quota «X» depending
on type of gas
Table of gas consumption 1W = 0,860 kcal/h
air
regul.
5 mm
5 mm
7 mm
6 mm
15 mm
13 mm
Loading ...
Loading ...
Loading ...